APW Wyott HDCB-2424i Скачать руководство пользователя страница 8

 

For first cooking, set the grates at maximum tilt position and preheat before broiling. You will have 
to experiment with knob settings and grate position for each particular item. 

 

Keep the grease/water pan with sufficient water to cover the entire bottom. 

 

Clean regularly. Grates may be removed for washing in the sink. Brush out carbonized particles. 
Thoroughly wash the grease/water pan. 

 

CAUTION 

Never attempt to move a grill section while cooking. An unexpected flare could cause severe injury. 
Turn off the unit, let it cool and use potholders and/or gloves to reposition or remove. The space 
between the legs at the bottom admits combustion air. DO NOT BLOCK THIS SPACE. 

Main burner air supply: 

For efficient burner operation, a proper balance of gas volume and primary air supply must be 
maintained which will result in complete combustion. Insufficient air supply results in a yellow streaming 
flame. Primary air supply is controlled by an air shutter on the front of the burner. 

Loosen the screws on the front of the burner, and adjust the air shutter to just eliminate the yellow tips 
of the burner flame. Lock the air shutter in place by tightening the screws. 

European Community: 

If adjustment becomes necessary in the field, it should be done by a factory authorized and 
trained technician who should  seal the screw  after the adjustment to safeguard  against   
un-authorized tampering by the end user. 

All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is all that 
is required to put the unit in service. 

Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the units' 
sides or back. Avoid wall type fans which create air cross-currents within a room. 

It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount 
of air removed by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur, 
affecting operation and causing undesirable working conditions. 

A properly designed and installed hood will act as the heart of the ventilating system for the room or 
area in which the unit is installed, and will leave the unit independent of changing draft conditions. 

All valves must be checked and lubricated periodically. This must be done by an authorized service 
representative in your area. 

Содержание HDCB-2424i

Страница 1: ...vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and mainten...

Страница 2: ...of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in a prominent place These may be obtained from the gas supplier GAS PRESSURE The applian...

Страница 3: ...ult in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or uns...

Страница 4: ...t the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue Adequate clearance for air openings into the combustion chamber is required Do not place objects...

Страница 5: ...1524 0 34 339 872 15 217 386 5 10 20 000 5 86 200 000 58 6 5 12 4 HDCB 2472i 72 1828 8 34 339 872 15 217 386 5 12 20 000 5 86 240 000 70 3 5 12 4 HDCRB 2424i 24 609 6 34 339 872 15 217 386 5 4 20 000...

Страница 6: ...ure With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or...

Страница 7: ...or remove the cooking grates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remov...

Страница 8: ...te the yellow tips of the burner flame Lock the air shutter in place by tightening the screws European Community If adjustment becomes necessary in the field it should be done by a factory authorized...

Страница 9: ...rners COOKING GRATES Place the top cooking grates with the grid bars sloping toward the front as shown in Sketch 2 SEASON GRIDDLE Heat to low temperature 300 350 F 150 180C and pour on a small amount...

Страница 10: ...scraper H Remove grates from broiler Clean top surface of radiants with the wire brush They may be cleaned in place WEEKLY Thoroughly clean the exposed surfaces of broiler sides front and top grease...

Страница 11: ...t light out Automatic pilot valve is bad Fat appears to smoke excessively Heat is set too high Moisture in the food may be turning into steam Food sticks to grates Heat is set too high Griddle surface...

Страница 12: ...12 EXPLODED VIEWS Domestic Version HDCB HDCRB GAS CHAR BROILER...

Страница 13: ...NA 1 1 1 1 2 2 2 2 7 21825126 Support Firebox NA NA 1 1 21825217 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829525 Manifol...

Страница 14: ...29 21825018 Guard Burner 4 6 8 11 12 30 21813129 Weldm t Grate Support 1 1 21813229 Weldm t Grate Support 1 1 21813329 Weldm t Grate Support 1 1 21825334 Weldm t Grate Support 1 1 21825434 Weldm t Gr...

Страница 15: ...15 EXPLODED VIEWS CE Version HDCB HDCRB GAS CHAR BROILER...

Страница 16: ...17 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829535 Manifold 24 CE 1 1 21829635 Manifold 36 CE 1 1 21829735 Manifold 48 CE...

Страница 17: ...5334 Weldm t Grate Support 1 1 21825434 Weldm t Grate Support 1 1 33 3103900 Grate Cooking Hvy Dty 4 4 6 6 8 8 10 10 12 12 34 21825031 Brace Leg 2 2 2 2 2 2 2 2 2 2 35 21826134 Channel Stiffiner NA NA...

Страница 18: ...HDCRB 2424i HDCB 2436i HDCRB 2436i HDCB 2448i HDCRB 2448i HDCB 2460i HDCRB 2460i HDCB 2472i HPDCRB 2472i 55 8806070 Label Delivery CE Gas Units N S 1 1 1 1 1 1 1 1 1 1 56 8806075 Label Packaging CE Un...

Страница 19: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Отзывы: