APW Wyott HDCB-2424i Скачать руководство пользователя страница 10

10 

CLEANING / MAINTENANCE 

INITIAL CLEANING: 

Prior to operating your new broiler, thoroughly wash the exterior with a mild detergent or soap solution. 
Do not use abrasive cleaners, since this might damage the cabinet finish. If the stainless steel 
surfaces become discolored, scrub by rubbing only in the direction of the finished grain. 

When the broiler is first heated, it will smoke until oil used in manufacturing, preservation and dust 
from storage and shipping are burned off. An hour at "max." on all burners is usually sufficient. 

CLEANING:  

DAILY 

Remove the grease pan, empty and wash it. 

Grate "burn off". The grease buildup on the grates should be cleaned daily (more often as needed). 

A. 

Caution:

 When handling grates or radiants, always use insulated gloves to prevent burns. 

B. 

Warning:

 Do not cover the top of the grid grates during a burn off operation. Restricting the 

airflow by covering the grid grates may cause them to warp. It will also cause damage to the 
valves, the knobs, the rock grates and the front panel decal. 

C.  Place grates on broiler, with grid bars horizontal, facing down.  

D.  Turn control knobs to "HI" for approximately 45 minutes. 

E. 

Turn off the broiler and allow it to cool for 20 Minutes. 

F.  Clean top and bottom surfaces of grate with a wire brush to remove animal fats and carbonized 

grease. 

G.  Clean channels on grates with a scraper. 

H.  Remove grates from broiler. Clean top surface of radiants with the wire brush. They may be 

cleaned in place. 

WEEKLY 

Thoroughly clean the exposed surfaces of broiler, sides, front and top grease trough, with a damp 
cloth, then polish with a soft, dry cloth. A detergent may be used for cleaning. To remove discoloration, 
use a non- abrasive cleaner. 

After performing daily cleaning procedures, proceed with the following: 

A. 

Remove the radiants or rock grates. Clean reflecting drip shield of any dust or debris with a brush. 

Note:

 Top cooking grates and rock grates are heavy. For applications where you use abundant 

sauces, radiants and rock grates should be cleaned more often. 

B. 

Burner air shutter openings must be kept clean. 

C. 

Burner ports must be kept clean. To clean burners, boil them in a strong solution of lye water for 
fifteen to twenty minutes. Then, either brush with a wire brush or clean gas ports with a sharp- 
pointed metal instrument to insure open ports

 

CAUTION: 

Clean the regulator at least once a month. Make sure the vent opening 

is open and not blocked in any way. Failure to do so will cause variations in 
pressure. Your unit will not function as well and it could shorten the life of the 
product. 

EXTENDED SHUTDOWN: 

Turn the manual shutoff valve to "OFF"; (*field installed valve not supplied by the manufacturer), turn 
all control knobs to the "OFF" position and shut off the pilot flame by turning the adjustment on the 
pilot valve. 

*NOTE:

 Gas shutoff valve is supplied by the manufacturer on CE or European Community models

Содержание HDCB-2424i

Страница 1: ...vicinity of this or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and mainten...

Страница 2: ...of combustibles See ANZI Z83 14B 1991 NOTICE Instructions to be followed if anyone smells gas should be posted in a prominent place These may be obtained from the gas supplier GAS PRESSURE The applian...

Страница 3: ...ult in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or uns...

Страница 4: ...t the flow of combustion and ventilation air under the unit by the legs or behind the unit by the flue Adequate clearance for air openings into the combustion chamber is required Do not place objects...

Страница 5: ...1524 0 34 339 872 15 217 386 5 10 20 000 5 86 200 000 58 6 5 12 4 HDCB 2472i 72 1828 8 34 339 872 15 217 386 5 12 20 000 5 86 240 000 70 3 5 12 4 HDCRB 2424i 24 609 6 34 339 872 15 217 386 5 4 20 000...

Страница 6: ...ure With the front panel removed remove the plug from the manifold Place a fitting in the plug opening and connect a manometer For Natural gas the pressure in the manifold should be 5 water column or...

Страница 7: ...or remove the cooking grates and light the pilot from above 4 Turn the manual shut off valve on 5 Hold an ignition source match to both openings on the pilot tube When the flames are established remov...

Страница 8: ...te the yellow tips of the burner flame Lock the air shutter in place by tightening the screws European Community If adjustment becomes necessary in the field it should be done by a factory authorized...

Страница 9: ...rners COOKING GRATES Place the top cooking grates with the grid bars sloping toward the front as shown in Sketch 2 SEASON GRIDDLE Heat to low temperature 300 350 F 150 180C and pour on a small amount...

Страница 10: ...scraper H Remove grates from broiler Clean top surface of radiants with the wire brush They may be cleaned in place WEEKLY Thoroughly clean the exposed surfaces of broiler sides front and top grease...

Страница 11: ...t light out Automatic pilot valve is bad Fat appears to smoke excessively Heat is set too high Moisture in the food may be turning into steam Food sticks to grates Heat is set too high Griddle surface...

Страница 12: ...12 EXPLODED VIEWS Domestic Version HDCB HDCRB GAS CHAR BROILER...

Страница 13: ...NA 1 1 1 1 2 2 2 2 7 21825126 Support Firebox NA NA 1 1 21825217 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829525 Manifol...

Страница 14: ...29 21825018 Guard Burner 4 6 8 11 12 30 21813129 Weldm t Grate Support 1 1 21813229 Weldm t Grate Support 1 1 21813329 Weldm t Grate Support 1 1 21825334 Weldm t Grate Support 1 1 21825434 Weldm t Gr...

Страница 15: ...15 EXPLODED VIEWS CE Version HDCB HDCRB GAS CHAR BROILER...

Страница 16: ...17 Support Firebox 1 1 21825317 Support Firebox 1 1 21825417 Support Firebox 1 1 8 21813085 Spacer 4 4 4 4 5 5 5 5 6 6 9 21829535 Manifold 24 CE 1 1 21829635 Manifold 36 CE 1 1 21829735 Manifold 48 CE...

Страница 17: ...5334 Weldm t Grate Support 1 1 21825434 Weldm t Grate Support 1 1 33 3103900 Grate Cooking Hvy Dty 4 4 6 6 8 8 10 10 12 12 34 21825031 Brace Leg 2 2 2 2 2 2 2 2 2 2 35 21826134 Channel Stiffiner NA NA...

Страница 18: ...HDCRB 2424i HDCB 2436i HDCRB 2436i HDCB 2448i HDCRB 2448i HDCB 2460i HDCRB 2460i HDCB 2472i HPDCRB 2472i 55 8806070 Label Delivery CE Gas Units N S 1 1 1 1 1 1 1 1 1 1 56 8806075 Label Packaging CE Un...

Страница 19: ...e conclusion of this warranty period portable units must be taken to or sent prepaid to the APW Wyott Authorized Service Agency for in warranty repairs No mileage or travel charges are allowed on port...

Отзывы: