![APW Wyott GCB-18S Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/apw-wyott/gcb-18s/gcb-18s_installation-and-operation-instruction-manual_2957334006.webp)
6
2M-Z23812: Gas Radiant & Lava Rock Charbr
oilers GCB & GCRB
PILOT LIGHTING INSTRUCTIONS
The charbroiler is equipped with standing pilots, and should be lit immediately after the gas is turned on.
1. Turn off main valve to unit.
2. Turn off all knobs and pilot valves and wait 5 minutes to clear gas.
3. Turn on main valve and light all pilots. The best access to the pilot is obtained from the bottom
with the grease drawer removed.
4. Adjust pilot light flames as small as possible, but high enough to light burner immediately when
burner valve is turned on high.
5. Turn burner knobs to desired setting.
6. To turn burners off, turn knobs off.
SHUTTING DOWN INSTRUCTIONS
Turn the burner valve knobs to the off position to turn burners off.
BURNER IGNITION AND ADJUSTMENT
1. To ignite burners turn burner valve knob to "HI" position.
2. Slowly decrease openings of air shutters on burners to give a soft blue flame having
luminous tips, then slowly increase openings to a point where the yellow tips disappear
and a hard blue flame is obtained.
PLACING LAVA ROCK ON GRATES
(FOR GCB SERIES)
Open the lava rock bags and place rock evenly on grates. Do not cover the grates with more than two
layers of lava rock.
DO NOT PUT MORE THAN 5 LBS. OF ROCK PER BURNER!
BURNER OPERATION
Each burner is controlled by an individual high-low, on-off valve. An infinite number of broiling temperatures
may be obtained by turning the burner valve knob to any position between high and low. It is possible
through this arrangement to have a high heat or searing section, while having a low heat finishing or
holding section. For the searing operation, set the valves for the section at a position of "HI" or close to
it. For holding or finishing, set the valves closer to the "LOW" position on the dial. You select the heat
pattern you like, and set the valves accordingly.