6.

Turn the burner knobs to "HI". If the burner does not ignite, promptly open the pilot valve more. If the

pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame

should be as small as possible but large enough to guarantee reliable ignition of the burners when

the knobs are turned to "HI".

7.

Replace the front panel and grease drawer.

Since the burner is lit from constantly burning pilot, turn knobs to "HI" to put the unit in operation; then, adjust

to any desired position between "LO" and "HI".

Main burner air supply:

1.

For efficient burner operation, a proper balance of gas volume and primary air supply must be

maintained which will result in complete combustion. Insufficient air supply results in a yellow

streaming flame. Primary air supply is controlled by an air shutter on the front of the burner.

2.

Loosen the screws on the front of the burner and adjust the air shutter to just eliminate the yellow tips

of the burner flame. Lock the air shutter in place by tightening the screws.

If adjustment becomes necessary in the field, it should be done by a factory authorized and trained

technician who should seal the screw after the adjustment to safeguard against unauthorized tampering by

the end user.

All burners are lit from constantly burning pilots. Turning the thermostat to the desired temperature is all

that is required to put the unit in service.

Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the units'

sides or back. Avoid wall type fans which create air cross-currents within a room.

It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of

air removed by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur, which will

effect operation and cause undesirable working conditions.

A properly designed and installed hood will act as the heart of the ventilating system for the room or area in

which the unit is installed and will leave the unit independent of changing draft conditions.

All valves and thermostats must be checked and lubricated periodically. Consult the authorized service

representative in your area.

Lighting main burner

European Community

OPERATING INSTRUCTIONS

Season Griddle:

Operation:

Heat to low temperature (300 - 350 F/150-180C) and pour on a small amount of cooking oil, about one

ounce (30cc) per square foot of surface. Spread the oil over the entire griddle surface with a cloth to create a

thin film. Wipe off any excess oil with a cloth. Repeat this procedure 2 to 3 times until the griddle has a slick,

mirror-like surface.

Turn the burners on about 15-20 minutes before cooking for preheating. Set the knobs to the desired flame

height or temperature. Each valve will control the gas flow to the burner to bring that area of the plate up to

the set temperature. If different temperature settings are to be used, adjoining areas should be set at

progressively higher temperatures using the lowest temperatures on the outside burners. A uniform and

systematic approach to the loading of the griddle will produce the most consistent product results.

Содержание Champion GGM-24H

Страница 1: ...4H 36H 48H MODELS GGM 24H 36H 48H WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before posi...

Страница 2: ...be followed if anyone smells gas should be posted in a prominent place These may be obtained from the gas supplier GAS PRESSURE The appliance and it s individual shutoff valve must be disconnected fro...

Страница 3: ...NGER This symbol warns of imminent hazard which will result in serious injury or death CAUTION This symbol refers to a potential hazard or unsafe practice which may result in minor or moderate injury...

Страница 4: ...FICATIONS AND DIMENSIONS GGT 24 24 610 26 661 17 3 4 451 2 25 000 7 3 50 000 14 6 6 10 15 25 GGT 36 36 915 26 661 17 3 4 451 3 37 500 11 75 000 22 6 10 15 25 GGT 48 48 1220 26 661 17 3 4 451 4 25 000...

Страница 5: ...TALLATION ON NON COMBUSTIBLE SURFACES ONLY EE LIGHTING INSTRUCTIONS GGT and GGM Griddles are furnished with either a pilot safety valve or a standing pilot not available in the European Community Plea...

Страница 6: ...pen windows next to the units sides or back Avoid wall type fans which create air cross currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensat...

Страница 7: ...asoned again If the griddle usage is very high the weekly cleaning procedures may be done more often than once a week Turn the manual shutoff valve to OFF field installed valve not supplied by the man...

Страница 8: ...resistance The valve will still regulate the temperature with the by pass turned off more than one turn Turning the adjuster screw to far counter clockwise will allow a gas leak around the screw that...

Страница 9: ...eaning and or seasoning Surface under food may not have been covered with enough cooking oil Food burned around edges or contains dark specks Surface under food may not have been covered with enough c...

Страница 10: ...4 24 34 44 44 15 15 25 25 35 45 45 26 26 36 46 46 27 37 37 37 47 47 28 38 48 19 29 39 49 20 20 30 30 50 Manifold with Safety Pilot Manifold with Safety Pilot Manifold with Standing Pilot 1 7 39 11 2 4...

Страница 11: ...4 L P Orifice 50 36 20668 50 20 On Off Valve 20680 00 21 Elbow 1 4 CC x 1 8 NPT 20926 15 23 Coupling 3 4 Pipe x 3 20926 10 24 Plug 1 8 Sq Head 20925 17 25 Nipple 3 4 Closed 20925 92 26 Elbow 3 4 Black...

Страница 12: ...2 toasters or rollergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply an...

Отзывы: