![APW Wyott Champion GGM-24H Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/apw-wyott/champion-ggm-24h/champion-ggm-24h_installation-and-operating-instructions-manual_2957606005.webp)
Caution:
European Community Installation Instructions:
DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and
water solution before operating unit.
Noncombustible clearances:
0" sides (0 mm)
6" rear (152 mm)
Do not obstruct the flow of combustion and ventilation air, under the unit by the legs or behind the unit by the
flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place objects
between the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the burners are
removable thru the front if the gas line is disconnected.
“THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON. IN THE UK, CORGI REGISTERED
INSTALLERS (INCLUDING THE REGIONS OF BRITISH GAS) UNDERTAKE TO WORK TO SAFE AND
SATISFACTORY STANDARDS. THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE
GAS SAFETY (INSTALLATION AND USE) REGULATIONS AND THE RELEVANT BUILDING
REGULATIONS / I
REGULATIONS. DETAILED RECOMMENDATIONS ARE CONTAINED IN THE
FOLLOWING BRITISH STANDARD CODES OF PRACTICE - BS 6172, BS 5440 PART 2, BS 6891"
"THISAPPLIANCE MUST BE INSTALLED INACCORDANCE WITH THE RULES IN FORCE”
"MUST BE INSTALLED INAWELLVENTILATEDAREA. Ventilation requirements ie. B.S. 5440."
THESE UNITSARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.
EE.
LIGHTING INSTRUCTIONS
GGT and GGM Griddles are furnished with either a pilot safety valve or a standing pilot (not available in the
European Community). Please follow the instructions for your unit.
Pilot Safety Valve Lighting Instructions
Standing Pilot Lighting Instructions
1.
Turn on main gas supply to unit, on-off valve located behind the unit (not supplied with unit).
2.
Turn the burner control knobs to "OFF" position. Open the front panel and wait at least 5 minutes
to allow any gas which may have accumulated in the firebox compartment to escape.
3.
Depress red button on the pilot safety valve and light through observation hole in firebox. Keep
red button on pilot safety depressed for at least 1 minute after pilot has lit. If pilot does not light,
repeat this step.
4.
To adjust the pilot flame, rotate knob next to the red button. Turning the knob clockwise
increases the pilot flame.Aproperly sized pilot should be 1/2" to 3/4" long (12/19 mm).
( NotAvailable in the European Community )
The pilot lights on the griddles have been set at the factory.Ascrewdriver maybe required for the first lighting
to adjust the flame for your elevation.
1.
Turn off the manual shut off valve and wait 5 minutes to clear the gas.
2.
Turn all knobs to the "OFF" position.
3.
Remove the grease drawer and front panel for easy access.
4.
Turn the manual shut off valve on.
5.
Hold an ignition source (match) at the pilot tube. When the flame is established, remove the ignition
source.
5