52
Note for parallel system:
1.
Only support common battery installation.
2.
Use custom-made RJ45 cable to connect any inverter (no need to connect to a specific inverter) and
Lithium battery.
Simply set this inverter battery type to “LIB” in LCD program 5. Others should be “USE”.
Step 2. Press manual ON/OFF button for 5 secs in the front panel, the battery will start up.
Step 3. Press more than three seconds to start Lithium battery, power output ready.
Step 4. Turn on the inverter.
Step 5. Be sure to select battery type as “LIB” in LCD program 5.
If communication between the inverter and battery is successful, the battery icon
on LCD display will
flash. Generally speaking, it will take longer than 1 minute to establish communication.