APsystems Microinverter QT2 Installation manual
11
4. APsystems Microinverter System Installation
AC connector interface as from left to right.
Figure 5
Cover any unused connectors with Bus Cable T-CONN Cap to protect the unused connectors.
Figure 6
4.3.6 Step 6 - Install a Bus Cable End Cap at the end of AC bus cable
A.
Wire stripping
B.
Set the parts on the cable
C.
Insert five wires into the core wires hole of the
body
D.
Insert seal and Clamp Finger into the body,
then tighten the nut, torque 2.5±0.5N.m
Figure 7
PE N L3 L2 L1
Nut / Claw Seal/ body/ Body