APS YC500A-MIW Скачать руководство пользователя страница 4

APS YC500A-MIW Installation/User Manual                    

 2   

RADIO INTERFERENCE STATEMENT

FCC Compliance: The equipment complies with the limits for a class 
B digital device, pursuant to part 15 of the FCC Rules, which are 
designed to protect against harmful interference in a residential 
installation. The equipment could radiate radio frequency energy 
and this might cause harmful interference to radio communications 
if instructions were not followed when installing and using the 
equipment. But there is no guarantee that interference will not 
occur in a particular installation. If this equipment causes harmful 
interference to radio or television reception, the following measures 
might resolve the issues: 

A) Relocate the receiving antenna and keep it well away from the 
equipment 

B) Consult the dealer or an experienced radio/TV technician for 
assistance. 

Changes or modifications not expressly approved by the party 
responsible for compliance may void the user’s authority to operate the 
equipment.

Radio Interference Statement

Содержание YC500A-MIW

Страница 1: ...tion User Manual APS YC500A MIW Photovoltaic Grid connected Inverter Version 4 1 7 2014 APS America 1015 Hostmark St Ste 104 Poulsbo WA 98370 TEL 206 855 5100 EMAIL info apsamerica com WEB www APSamer...

Страница 2: ...ecting the APS Microinverter to the PV Module 9 Step 4 Ground the System 10 Step 5 Connecting APS Microinverters to the AC Cables 11 Step 6 Completing the APS Installation Map 12 APS Microinverter sys...

Страница 3: ...imized Microinverter operation Follow these instructions closely SAFETY INSTRUCTIONS Do NOT disconnect the PV module from the APS Microinverter without first disconnecting the AC power Only qualified...

Страница 4: ...tructions were not followed when installing and using the equipment But there is no guarantee that interference will not occur in a particular installation If this equipment causes harmful interferenc...

Страница 5: ...Introduction The APS Microinverter is used in utility interactive grid tied applications comprised of three key elements APS Microinverter APS Energy Communication Unit ECU APS Energy Monitor and Ana...

Страница 6: ...failure exists across the PV system APS Microinverters are designed to operate at full power at ambient outdoor temperatures of up to 149 F 65 C The inverter housing is designed for outdoor installati...

Страница 7: ...Technical Data page p 18 of this manual The APS YC500 has two independent DC inputs each with independent MPPT control and data monitoring The following figure shows the APS YC500 Microinverter schema...

Страница 8: ...please read all instructions and warnings in the technical documents and on the APS Microinverter system itself as well as on the PV array WARNING Be aware that installation of this equipment includes...

Страница 9: ...Installing the AC Branch Circuit Junction Box A Install an appropriate junction box at a suitable location on the PV racking system typically at the end of a branch of modules B Connect the open wire...

Страница 10: ...rters to the Racking or the PV Module Frame A Mark the location of the Microinverter on the rack keeping in mind the PV module junction box or any other obstructions B Mount one Microinverter at each...

Страница 11: ...p 3 Connecting APS Microinverters to the PV Module Connect the DC cables from the PV Modules to the Micro Inverter per the diagram below Note When plugging in the DC cables the Microinverter should im...

Страница 12: ...washers WEEB to ground the Microinverter chassis to the PV module racking as described in Step 2C skip this step Each APS Microinverter comes with a ground clamp that can accommodate a single 6 awg st...

Страница 13: ...circuit B Install a protective end cap on the open AC connector of the last Microinverter in the AC branch circuit C Plug the AC female connector of the last Microinverter into the male connector of...

Страница 14: ...d is designed to accomodate labels in vertical or horizontal orientation to meet all the field PV connections 1 Each APS Microinverter has removable serial number labels Peel a label off and affix it...

Страница 15: ...they are producing power normally but have not yet connected to the ECU After the ECU has been plugged in and acknowledges the Microinverters they will start to blink green every 10 seconds 4 Plug in...

Страница 16: ...ss the GFDI error has been cleared the LED will remain red and the ECU will keep reporting the fault After the ground fault error is fixed follow the instructions in the ECU Installation and Operation...

Страница 17: ...eans it is definitely a Microinverter problem 2 Diagnosing from the ECU a No Data Display This is probably a communication issue not a Microinverter problem b Problems with erratic display Data is dis...

Страница 18: ...y grid as described in the previous step 4 Make sure that all AC breakers are functioning properly and are closed 5 Check the DC connections between the Microinverter and the PV module 6 Verify the PV...

Страница 19: ...3 Disconnect the PV module DC wire connectors from the micro inverter 4 Remove the Microinverter from the PV array racking B Install a replacement Microinverter to the rack Remember to observe the fl...

Страница 20: ...er Refer to the APS website http www altenergy power com for a list of approved PV modules WARNING You must match the DC operating voltage range of the PV module with the allowable input voltage range...

Страница 21: ...y 99 5 MECHANICAL DATA Storage Temperature Range 40 F to 185 F 40 C to 85 C Operating Temperature Range Ambient 40 F to 149 F 40 C to 65 C Operating Temperature Range Internal 40 F to 185 F 40 C to 85...

Страница 22: ...ncy temperature Curves YC500 NA Efficency Curves ALTENERGY POWER SYSTEM INC 8 Efficiency Curves YC500 NA Efficiency temperature Curves YC500 NA Efficiency Curves ALTENERGY POWER SYSTEM INC 8 Efficienc...

Страница 23: ...APS YC500A MIW Installation User Manual 21 Figure 11 Sample Wiring Diagrams Sample Wiring Diagram 120V 240V Three Phase...

Страница 24: ...APS YC500A MIW Installation User Manual 22 NOTE The ECU should function properly when connected to L1 L2 or L3 Figure 12 Sample Wiring Diagram 120V 208V Three Phase...

Страница 25: ...tion User Manual 23 NOTE The ECU should function properly when connected to L1 L2 or L3 Figure 13 Sample Wiring Diagram 277V 480V Three Phase ALTENERGY POWER SYSTEM INC 24 10 3 Sample Wiring Diagram 2...

Отзывы: