![APS Presco WD7102 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/aps/presco-wd7102/presco-wd7102_operating-manual_2956867015.webp)
COLLISION ALERT SYSTEMS
APS-SUPPLY.COM
www.aps-supply.com
APS USA
610 Gateway Center Way, Suites J & K
San Diego, CA 92102 USA
P: 1 619 263 4164
F: 1 619 263 6814
APS Australia
U48 / 9 Vision Street,
Wangara WA 6065 Australia
P: 61 (8) 9302 2369
F: 61 (8) 6305 0047
APS: Singapore
Colombia
Chile
Perú
Brasil
Troubleshooting
Display will not turn on:
•
Verify that DC power (9-33V) is applied to the display.
•
Verify that the display has a solid ground connection.
Display cannot find or connect to the wireless sensor:
•
Verify that DC power (9-33V) is applied to the sensor.
•
Sensor may be out of range. Contact Preco Electronics for assistance.
“Not In Reverse” message is present, but machine is in reverse:
•
Verify display is configured properly, see page 6.
•
For installation method A (see page 3), verify reverse connection has 9-33V
present.
•
For installation method B (see page 3), verify sensor is powered and
communicating.
“Connection to Sensor Failed!” message is present:
•
Verify display is configured properly, see page 6.
•
Verify sensor is powered and communicating, see page 6.
“Sensor BIST Failure!” message is present:
•
Contact Preco Electronics for assistance.
There is a constant detection even if there is no object in the
machines vicinity:
•
Check for any objects on the machine that the sensor may be detecting.
Relocate the sensor so it does not see these objects.
•
If the detection is showing up in Zone 4 or 5, the sensor may be detecting the
ground. In an open field, either move the sensor up higher or slightly angle
the sensor upward 5 to 10 degrees. The minimum recommended mounting
height is 24 inches.