![Aprilaire Control4 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/aprilaire/control4/control4_user-manual_2956202008.webp)
5
Program schedule and holds
Off:
Ventilation will not run.
Automatic:
Ventilation will cycle based on the parameters set by
the installer to meet your home’s ventilation requirements.
3 Hour Event:
Ventilation will be constantly energized for 3
hours and then the fresh air mode will return to
Off
or
Automatic
depending on which was mode was most recently active. This
option is used when fresh air is needed. An example would be
after cooking.
24 Hour Event:
Ventilation will be constantly energized for 24
hours and then the fresh air mode will return to
Off
or
Automatic
depending on which was mode was most recently active. This
option is used when a large amount of fresh air is desired. An
example would be a day with desirable outdoor conditions.
Fresh Air screen
Fresh Air
If ventilation is installed
, Fresh Air can operate in four different
modes as defined on this page.
Press
button to select
Fresh Air
and enter the Fresh Air
screen.
Fresh Air mode
adjustment
Done button
(save mode and
exit Fresh Air)
Fresh Air mode
selection
Program schedule and holds
Understanding program schedules
Setting the schedule for the thermostat is done at the Control4
system. Refer to the
Control4 End User Climate Control
instructions
for specific instructions for managing the thermostat
schedule.
The thermostat is shipped with programming disabled. Schedules
and program hold functionality will not be available until
programming is enabled by the Control4 system. If programming
is disabled, a program disabled message will appear in the
message center when the button is pressed.
Progressive recovery
The Progressive Recovery feature allows the thermostat to
activate the heating and cooling equipment
prior
to a scheduled
event in order to reach the desired temperature at the start of
that scheduled event.
Example:
If the Next Event time is 6 a.m., and the temperature is
70°, the heat will come on before 6 a.m., so the temperature is
70° by 6 a.m.
Equipment wait
The thermostat implements equipment protection by enforcing
minimum equipment on and off times. If equipment is prevented
from coming on due to equipment protection an equipment
wait message will appear in the message center and the
corresponding equipment status icon will flash.