background image

2

Operation

Operation

Select system mode  

(Em Heat/Heat/Off/Cool/Auto)

Press 

 button to select: 

Em Heat:

 (only for heat pumps with auxiliary heat) Thermostat 

controls auxiliary heat. Heat pump will not operate in 

Em Heat

 

mode.

Heat:

 Thermostat controls only the heating system.

Off:

 Heating and cooling systems are off.

Cool:

 Thermostat controls only the cooling system.

Auto:

 (if enabled in installer setup) Thermostat automatically 

selects heating or cooling depending on the indoor temperature. 

The current system mode selection will flash. After 5 seconds 

without any button presses, the selected system mode will be 

accepted by the thermostat. 

Change temperature setpoint

Press   or   buttons to adjust the current setpoint. See 

Program 

schedule and holds

 on pages 5-6 for more information. 

Select fan setting (On/Auto/Circ)

When the fan mode is changed during a program event it 

remains in that mode until the next event starts. The fan must 

be programmed to FAN ON in the schedule to run continuously 

through all events.

Press   button to select:

On:

 Fan runs continuously. Use this mode for maximum air 

circulation/filtering.

Auto:

 Fan runs only when the heating or cooling system is on.

Circ:

 Same as 

Auto

, but ensures the fan is on for at least 30 

minutes per hour. Use this mode for a balance of energy savings 

and air circulation/cleaning.

The current fan selection will flash. After 5 seconds without any 

button presses, the selected fan mode will be accepted by the 

thermostat. 

Maintenance reminders

Maintenance reminders are set up by the installer to indicate 

when the equipment is due for service. If a maintenance reminder 

is displayed, call your HVAC dealer for service. Maintenance 

reminders can be cleared by setting the system mode to off and 

then holding the   button continuously for 5 seconds. When 

prompted to Service Reminders, press the   or   button to 

select 

Yes

, then press   button (Next). Press   or   button to 

select 

Yes

 for each reminder you would like to reset. Press   

button (Next) to go to the next reminder or   button (Back) to 

go to a previous reminder. Press 

 button (Done) to reset the 

selected service reminders.

Maintenance reminders can also be reset from the Control4 

system. Refer to the 

Control4 End User Climate Control 

instructions

 for specific instructions on how to reset maintenance 

reminders. 

Screen lockout

Certain features of the thermostat can be locked so that changes 

at the thermostat are not allowed. This feature can be overridden 

by pressing and holding 

 button for 5 seconds.

Содержание Control4

Страница 1: ...Control4 Wireless Thermostat by Aprilaire User Guide ...

Страница 2: ...uct does not convey a license nor imply any right to distribute content created with this product in revenue generating broadcast systems terrestrial satellite cable and or other distribution channels streaming applications via Internet intranets and or other networks other content distribution systems pay audio or audio on demand applications and the like or on physical media compact discs digita...

Страница 3: ...e reminders 2 Screen lockout 2 Power and battery replacement 3 Indoor Air Quality functions 3 Event Based air cleaning 3 Humidifier control 3 Automatic mode 3 Manual mode 4 Dehumidifier control 4 If dehumidification is installed 4 If dehumidification is done with the air conditioner 4 Fresh air 5 Program schedule and holds 5 Understanding program schedules 5 Progressive recovery 5 Equipment wait 5...

Страница 4: ...ode setting System Mode button Hold button Fan Mode button Indoor Air Quality button optional Setpoint Adjust buttons Temperature setting Fan Mode setting Presets button Hold status Radio signal strength indicator Low battery indicator Message center Indoor Air Quality setting Current indoor temperature Supported model C4 THERM WH Thermostat Important safety instructions Warning Install in accorda...

Страница 5: ...ting or cooling system is on Circ Same as Auto but ensures the fan is on for at least 30 minutes per hour Use this mode for a balance of energy savings and air circulation cleaning The current fan selection will flash After 5 seconds without any button presses the selected fan mode will be accepted by the thermostat Maintenance reminders Maintenance reminders are set up by the installer to indicat...

Страница 6: ...can be controlled in two modes automatic or manual Press button to select Humidify and enter the Humidifier Control screen Indoor Air Quality functions Event Based air cleaning If installed air cleaning can be controlled through the Control4 system See the Control4 End User Climate Control instructions for specific instructions on this feature Note that air cleaning cannot be controlled directly f...

Страница 7: ...f time that dehumidification runs Lower the setting if you prefer the air to be more dry this will increase the amount of time that dehumidification runs Your comfort is the best measure of how to adjust your setting When first installed your dehumidifier has to remove all the moisture that is initially in your home The home acts like a sponge so the moisture in the materials of your home is at th...

Страница 8: ...ir mode selection Program schedule and holds Understanding program schedules Setting the schedule for the thermostat is done at the Control4 system Refer to the Control4 End User Climate Control instructions for specific instructions for managing the thermostat schedule The thermostat is shipped with programming disabled Schedules and program hold functionality will not be available until programm...

Страница 9: ... the thermostat control screen in any Control4 user interface Scheduling All scheduling for this thermostat is managed from the Control4 user interface It is not possible to adjust schedules from the thermostat itself Scheduling is made easy by using the Presets feature described above Creating a scheduled event simply requires picking a time of day and the preset that should be activated at that ...

Страница 10: ...control4 com 888 400 4070 200 40001 A 90 1883 3 15 ...

Отзывы: