background image

Thermostat installation location recommendations  .  .  . 2
Thermostat mounting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Equipment control module installation location 

recommendations .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Equipment control module mounting   .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Thermostat wiring   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Remote temperature sensor (optional)   .  .  .  .  .  .  .  .  .  .  .  .  . 3
Equipment control module wiring  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Outdoor temperature sensor (included) .  .  .  .  .  .  .  .  .  .  .  .  . 5
Optional wireless outdoor temperature  

and humidity sensor   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Return air temperature sensor (optional)   .  .  .  .  .  .  .  .  .  .  . 6
Leaving air temperature sensor (optional)   .  .  .  .  .  .  .  .  .  . 6

Wi-Fi Setup   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

TABLE OF CONTENTS

INSTALLATION

WI-FI SETUP

POWER & RESET OPTIONS

SETUP & TESTING

REFERENCES

Power and reset options   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

Removal of Indoor Air Quality control buttons   .  .  .  .  .  . 10
Equipment type selection switch (SW1)  .  .  .  .  .  .  .  .  .  .  . 11
Installer setup menu   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11
Change system settings .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 11
HVAC installer system settings table   .  .  .  .  .  .  .  .  .  . 12-13
Indoor Air Quality system settings tables .  .  .  .  .  .  . 14-16
   Air cleaning system settings table .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
   Humidifier system settings table  .  .  .  .  .  .  .  .  .  .  .  . 14-15
   Dehumidifier system settings table  .  .  .  .  .  .  .  .  .  .  .  .  . 15
   Ventilation system settings table .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16
System test menu   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17-18 
System test tables .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 18-20

Quick reference to controls & display .  .  .  .  .  .  .  .  .  . 21-22
Troubleshooting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 22-23
Error codes  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 23
Thermostat features   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 23
Specifications .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 24

HVAC WIRING DIAGRAMS

Conventional heat/cool single transformer .  .  .  .  .  .  .  .  .  . 7
Conventional heat/cool two transformer   .  .  .  .  .  .  .  .  .  .  . 7
Heat pump single transformer .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
Heat pump two transformer   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8

INDOOR AIR QUALITY WIRING DIAGRAMS

Indoor Air Quality wiring with separate transformers  .  .  . 9
Indoor Air Quality wiring with a single transformer .  .  .  .  . 9

Model 8910W Touch Screen  

Wi‑Fi Thermostat with Integrated 

Indoor Air Quality Solutions

Includes Wired Outdoor Temperature Sensor

Safety & Installation 
Instructions

READ AND SAVE THESE INSTRUCTIONS

61001131 B2206504E 4.18

English

 1

Содержание 8910W

Страница 1: ...stem settings table 12 13 Indoor Air Quality system settings tables 14 16 Air cleaning system settings table 14 Humidifier system settings table 14 15 Dehumidifier system settings table 15 Ventilation system settings table 16 System test menu 17 18 System test tables 18 20 Quick reference to controls display 21 22 Troubleshooting 22 23 Error codes 23 Thermostat features 23 Specifications 24 HVAC W...

Страница 2: ...CONTROL MODULE MOUNTING 1 Remove the rear mounting plate from the thermostat 2 Pull wires through the opening on the rear mounting plate 3 Position and level the mounting plate of the thermostat on wall and mark the hole locations with a pencil 4 Drill 1 4 holes and insert supplied anchors drywall only 5 Place mounting plate over anchors insert and tighten screws 6 Seal wire entry holes to prevent...

Страница 3: ...2 sensor to the ODT terminals and enabling the outdoor sensor in the installer set up menu When an outdoor sensor is installed the features below will be enabled In heat pump mode the outdoor temperature sensor can be used to efficiently utilize an air source heat pump When the outdoor temperature is less than the Low Balance Point the heat pump will be locked out and only auxiliary heating will b...

Страница 4: ...OLING LOCATE SENSOR IN SHADED AREA CONVENTIONAL HEAT COOL TWO TRANSFORMER REMOVE JUMPER HEATING TRANSFORMER COOLING TRANSFORMER C R W W2 B Y Y2 O G L RH RC C 3 EQ HP HC G Y3 Y2 Y W3 W2 W TRANSFORMER THERMOSTAT 1 2 2nd COOLING 1st COOLING FAN 1st HEATING 2nd HEATING 3rd HEATING 3rd COOLING 1 R and C can be powered from the HVAC equipment transformer or any other constantly powered 24VAC source 1 RE...

Страница 5: ...FAULT DETECT REVERSING VALVE REVERSING VALVE 2nd HEATING 1st HEATING FAN 1st COMPRESSOR 2nd COMPRESSOR 2 1 1 R and C can be powered from the HVAC equipment transformer or any other constantly powered 24VAC source INDOOR AIR QUALITY WIRING DIAGRAMS INDOOR AIR QUALITY WIRING WITH SEPARATE TRANSFORMERS INDOOR AIR QUALITY WIRING WITH A SINGLE TRANSFORMER TRANSFORMER TRANSFORMER TRANSFORMER VNT DH HUM ...

Страница 6: ... adjust the setting Press DONE to save and exit or CANCEL to exit without saving The thermostat will discard changes and exit if nothing is pressed within 60 seconds To reset the installer settings to the default reset the thermostat by pressing the RESET button for 5 seconds SETTING NUMBER SETTING DESCRIPTION SETTING OPTIONS EQUIPMENT TYPE SELECTION SWITCH SW1 This thermostat has the option of be...

Страница 7: ... SETUP TESTING SETUP TESTING HVAC INSTALLER SYSTEM SETTINGS TABLE CONTINUED The following table contains the system settings and their details Default settings are shown in bold Some settings are only available dependent upon the value of other settings HVAC INSTALLER SYSTEM SETTINGS TABLE System setting Description Factory default setting bold and setting range 01 Equipment Type Equipment type se...

Страница 8: ...umidifier is installed on the HVAC duct Without airflow moisture can accumulate in the duct resulting in significant damage Change Water Panel Reminder Selects the when the Change Water Panel message is displayed Off 1 Per Season 2 Per Season 300 Hours 600 Hours INDOOR AIR QUALITY SYSTEM SETTINGS TABLES Dehumidifier System Settings Table System setting Description Factory default setting bold and ...

Страница 9: ...imit Sets low ventilation temperature lockout limit Only available if Enable Low Vent Temperature Limit is set to Yes 10 F 12 C 10 F to 40 F 24 C to 6 C HVAC Fan with Vent Selects if ventilation forces the fan on Yes with high and low limits is only available if Outdoor Sensor is set to Installed Yes Yes with high and low limits No Enable High Mixing Temperature Enables high mixing temperature Onl...

Страница 10: ...Heat Compressor Stages Aux Stages W W2 B Y Y2 O G 1 1 1st Stage Test ON ON ON 1 1 2nd Stage Test ON ON ON ON 2 1 1st Stage Test ON ON ON 2 1 2nd Stage Test ON ON ON ON 2 1 3rd Stage Test ON ON ON ON ON 1 2 1st Stage Test ON ON ON 1 2 2nd Stage Test ON ON ON ON 1 2 3rd Stage Test ON ON ON ON ON 2 2 1st Stage Test ON ON ON 2 2 2nd Stage Test ON ON ON ON 2 2 3rd Stage Test ON ON ON ON ON 2 2 4th Stag...

Страница 11: ...MATICALLY TURNS OFF FAN MODE BUTTON FAN MODE SETTING SYSTEM MODE BUTTON SYSTEM MODE SETTING WI FI SIGNAL STRENGTH CURRENT TIME DATE MAIN MENU BUTTON HEAT BLAST BUTTON TEMPERATURE ADJUSTMENT AIR CLEANING BUTTON ENTERS EVENT BASED AIR CLEANING CONTROL SCREEN HUMIDITY CONTROL BUTTON ENTERS HUMIDITY CONTROL SCREEN FRESH AIR BUTTON ENTERS VENTILATION CONTROL SCREEN HOLD BUTTON SETS OR CLEARS HOLD HEAT ...

Страница 12: ...s connected to the proper terminal O is active in cooling and B is active in heating HEAT COOL BOTH ON AT SAME TIME EQUIPMENT CONTROL MODULE LEDs Check SW1 Equipment Type to make sure it is set to match the installed heating cooling equipment Check to make sure heating and cooling wires are not shorted together HEATING EQUIPMENT IS RUNNING IN COOL MODE Check SW1 Equipment Type to make sure it is s...

Страница 13: ... to 50 R H Dehumidification 40 to 90 R H SPECIFICATIONS Electrical Operating voltage 24VAC 18 30VAC Current Maximum 2 5A total 1 0A single output Maximum surge current 5A Environment Temperature Shipping 30 to 150 F 34 to 65 C Temperature Thermostat Operating 32 to 120 F 0 to 48 C Temperature Equipment Control Module Operating 32 to 158 F 0 to 70 C Relative humidity Operating 5 to 90 R H non conde...

Страница 14: ...ire interior 14 16 Tabla de configuración del sistema de purificación de aire 14 Tabla de configuración del sistema del humidificador 14 15 Tabla de configuración del sistema del deshumidificador 15 Tabla de configuración del sistema de ventilación 16 Menú de prueba del sistema 17 18 Tablas de prueba del sistema 18 20 Referencia rápida sobre los controles y la pantalla 21 22 Solución de problemas ...

Страница 15: ...to 2 Tire de los cables a través de la abertura de la parte posterior de la placa de montaje 3 Coloque y nivele la placa de montaje del termostato en la pared y utilice un lápiz para marcar las ubicaciones de los orificios 4 Realice orificios de 1 4 in y coloque los anclajes que se proporcionan solo para panel de yeso 5 Coloque la placa de montaje sobre los anclajes inserte y ajuste los tornillos ...

Страница 16: ... al habilitar el sensor exterior desde el menú de configuración del instalador Si se instala un sensor exterior se activarán las funciones mencionadas a continuación En el modo de bomba de calor se puede utilizar el sensor de temperatura exterior para utilizar de forma eficiente una bomba de calor de fuente de aire Cuando la temperatura exterior es menor que el Low Balance Point punto de equilibri...

Страница 17: ... Ï1 7 3 Ï1 7 3 1 5 0 172 7 3 COLOQUE EL SENSOR EN EL ÁREA SOMBREADA SISTEMA DE CALOR FRÍO CON DOS TRANSFORMADORES CONVENCIONALES RETIRAR PUENTE DE CONEXIÓN TRANSFORMADOR DE LA CALEFACCIÓN TRANSFORMADOR DEL SISTEMA DE ENFRIAMIENTO 5 2 5 5 4 3 TRANSFORMADOR 7 50267 72 1 5 0 172 7 3 1 5 0 172 7 3 9 17 25 Ï1 7 3 Ï1 7 3 Ï1 7 3 1 5 0 172 7 3 R y C pueden recibir alimentación desde el transformador del e...

Страница 18: ...N 7 7 5 9È 98 19 56 Ï1 9È 98 19 56 Ï1 2035 625 7 3 2035 625 7 3 9 17 25 Ï1 7 3 Ï1 7 3 R y C pueden recibir alimentación desde el transformador del equipo de HVAC o desde cualquier otra fuente de 24 VCA que reciba energía constantemente DIAGRAMAS DE CABLEADO DEL SISTEMA DE CALIDAD DEL AIRE INTERIOR CABLEADO DEL SISTEMA DE CALIDAD DEL AIRE INTERIOR CON TRANSFORMADORES INDIVIDUALES CABLEADO DEL SISTE...

Страница 19: ...Ahora se pueden modificar las configuraciones del sistema Presione NEXT Siguiente o BACK Atrás para revisar las configuraciones Presione o para ajustar la configuración Presione DONE Listo para guardar y salir o CANCEL Cancelar para salir sin guardar los cambios Si no se presiona nada en 60 segundos el termostato descartará los cambios y saldrá de la pantalla Para restablecer la configuración del ...

Страница 20: ...e la configuración del sistema y detalles de la configuración La configuración predeterminada se muestra en negrita Algunas opciones de configuración están disponibles según el valor de otras opciones TABLA DE CONFIGURACIÓN DEL SISTEMA DEL INSTALADOR DE HVAC Configuración del sistema Descripción Configuración por defecto de fábrica negrita y rango de configuración 01 Equipment Type Tipo de equipo ...

Страница 21: ...mular humedad en el conducto y como resultado provocador daños importantes Change Water Panel Reminder Aviso de cambio del panel de agua Seleccione esta opción cuando aparece el mensaje Change Water Panel Cambiar panel de agua Apagado 1 por temporada 2 por temporada 300 horas 600 horas TABLAS DE CONFIGURACIÓN DEL SISTEMA DE CALIDAD DEL AIRE INTERIOR Tabla de configuración del sistema del deshumidi...

Страница 22: ...ent Temperature Limit Habilitar límite inferior de la temperatura de ventilación Permite habilitar el límite inferior de bloqueo de la temperatura del sistema de ventilación Solo estará disponible si la opción Outdoor Sensor Sensor exterior se establece en Installed Instalado No Sí Low Vent Temperature Limit Límite inferior de la temperatura de ventilación Permite establecer el límite inferior de ...

Страница 23: ...O ENCENDIDO 2 1 Prueba de 2 º etapa ENCENDIDO ENCENDIDO ENCENDIDO ENCENDIDO 2 1 Prueba de 3 º etapa ENCENDIDO ENCENDIDO ENCENDIDO ENCENDIDO ENCENDIDO 1 2 Prueba de 1 º etapa ENCENDIDO ENCENDIDO ENCENDIDO 1 2 Prueba de 2 º etapa ENCENDIDO ENCENDIDO ENCENDIDO ENCENDIDO 1 2 Prueba de 3 º etapa ENCENDIDO ENCENDIDO ENCENDIDO ENCENDIDO ENCENDIDO 2 2 Prueba de 1 º etapa ENCENDIDO ENCENDIDO ENCENDIDO 2 2 ...

Страница 24: ... APAGA DE MANERA AUTOMÁTICA BOTÓN DEL MODO VENTILADOR CONFIGURACIÓN DEL MODO VENTILADOR BOTÓN DEL MODO SISTEMA CONFIGURACIÓN DEL MODO SISTEMA INTENSIDAD DE LA SEÑAL DE WI FI HORA Y FECHA ACTUAL BOTÓN DEL MENÚ PRINCIPAL BOTÓN DEL MODO RÁFAGA DE CALOR AJUSTE DE LA TEMPERATURA BOTÓN DEL SISTEMA DE PURIFICACIÓN DE AIRE INGRESA A LA PANTALLA DE CONTROL DEL SISTEMA DE PURIFICACIÓN DE AIRE EVENT BASED BO...

Страница 25: ... modo calefacción LAS OPCIONES CALOR FRÍO ESTÁN ENCENDIDAS AL MISMO TIEMPO LUCES LED DEL MÓDULO DE CONTROL DEL EQUIPO Verifique la función SW1 Equipment Type Tipo de equipo para asegurarse de que esté configurada de modo que coincida con el equipo del sistema de calefacción y enfriamiento instalado Verifique que los cables del sistema de calefacción y enfriamiento no estén en cortocircuito EL EQUI...

Страница 26: ...cación de 10 a 50 de R H Deshumidificación de 40 a 90 de R H ESPECIFICACIONES Información eléctrica Voltaje de funcionamiento 24 VCA de 18 a 30 VCA Corriente Máxima 2 5 A total 1 0 A salida única Sobrecorriente máxima 5 A Ambiente Temperatura de envío De 30 a 150 F de 34 a 65 C Temperatura del termostato en funcionamiento De 32 a 120 F de 0 a 48 C Temperatura del módulo de control del equipo en fu...

Отзывы: