background image

7. System Error and Trouble Shooting 

 

7.1 Indicator lights 

 

There are three LED indicator lights on the panel:  
1)”POWER” is the power supply indicator, illuminates (in red) to show power supply is 
working orderly.  
2)”STATUS” illuminates (in green) to show the input signal is in order.  
3)”ALARM” illuminates (in green) to show all parts are working orderly  

 
7.2 Trouble Shooting  

 

7.2.1 The ”POWER” indicator light does not illuminate.  

Please check the wire to make sure the wire is connected to the socket properly and the 
power switch is on.  
 

7.2.2”STATUS” illuminates (in red)  

This means the parameters are been setting.  
 

7.2.3”AlARM”flashes  

This means the unit is out of order, pleas refer to following:  
It shows “ IN TS NO SIGNAL”: The input signal of ASI interface is not in order or no 
input signal. Please check the ASI input signal source and connecting cable.  
It shows “CH01 FIFO FULL”: There is some data overflow from the first input interface, 
the signal will have the error coding and the unit can’t work orderly. It needs to increase 
output data rate or deduce the output programs.  

 

7.3 Note  

 

A. The output bit rate of MUX should be slight higher than the summation of input  

bit rate, otherwise the MUX will work unorderly.  

 

 

B. The output bit rate of MUX should be slight lower than the input bit rate of QAM  

modulator.  

 

 

C. The relation between input available bit rate of QAM modulator and symbol rate  

of IRD-C:  

Input available bit rate =symbol rate * 

m *

188/204  

Input available bit rate is 188 bytes data.  
For Example: Input available bit rate = 38.014Mbps (64 QAM modulation)  
Symbol rate= Input available bit rate* 204 

/

188

/

6=6875Kbps  

m=2,4,5,6,7,8,  
correspondence to QPSK,16QAM,32QAM,64QAM,128QAM,256QAM  

 
 
 
 
 
 
 

7-1

Содержание AD2700

Страница 1: ...AD2700 DVB REMULTIPLEXER USER S MANUAL...

Страница 2: ...ERFACE 4 4 KEEP STATUS OF POWER OFF 4 5 POWER SUPPLY 4 6 WORKING ENVIRONMENT 4 7 RADIATION AND SAFETY 4 8MECHANICS CHARACTERISTICS 5 EQUIPMENT CONNECTION 5 1 5 1 PANEL DISPLAY 5 2 FRONT PANEL SKETCH 5...

Страница 3: ...o avoid risk of electric shock 1 5 Please pull the plug itself instead of the wire when you pull out power plug 1 6 Any thing flammable and metal or liquid which will destroy the unit must be kept out...

Страница 4: ...nput it s MPTS Multi Program Transport Stream or SPTS The useful data will be output and null packet needless data will be filtered after processing 2 1 2 Program stream multiplexing Multiplex the sel...

Страница 5: ...D2700 TS REMULTIPLEXER multiplex 2 8 MPEG 2 SPTS or MPTS into 1 MPTS the null packet or needless packet will be filtered The PID could be reset if necessary and pick up the relevant information for fu...

Страница 6: ...d input through channel ETHERNET interface it could carry out the parameters setup and supervision from remote via network management unit Statistic multiplexing PCR correction Insert network paramete...

Страница 7: ...e 75 Encoding format HDB3 TS packet format 188 204 bytes Data bit rate E3 non frame 34 368Mbps 4 2 3 DS3 output optional Standard G703 Connector BNC Impedance 75 Encoding format B3ZS TS packet format...

Страница 8: ...5 Equipment connection 5 1 Panel display POWER STATUS ALARM 5 2 Front panel sketch 5 1 AD2700 Front panel as above 5 3 Rear panel sketch 5 2 AD2700 Rear panel as above 5 1...

Страница 9: ...parameters 6 2 Select MENU keyboard unlocked 6 2 1 Main menu display Press MENU to display contents in main menu in recycle or press ENTER to display contents in main menu in recycle ONCE 1 0 VIEW AL...

Страница 10: ...2 SET NET MASK 255 255 255 000 3 1 3 SET NET GATE 120 120 120 001 4 1 4 NET STATUS NOT CONNECTED or CONNECTED 5 1 5 SERIAL No XXXXXXXXXXXXXXXXXX 18 digit 6 1 6 VERSION H XX XX S XX XX 7 1 7 GET PRESET...

Страница 11: ...m name 2 01 0 PROG01 NAME DWtv 41 2 01 1 PROG01 IN CHA01 REMULTIPLEXED Press UP DOWN to change and press ENTER to confirm NOT BE REMULTIPLEXED 42 2 01 2 PROG01 CODE RATE 004 391Mbps 43 2 01 3 PROG01 P...

Страница 12: ...DWtv changeable 42 10 01 2 PROG01 CODE RATE 004 391Mbps read only 43 10 01 3 PROG01 PCR PID 0A82 HEX 2690 DEC changeable 44 10 01 5 PROG01 MPEG 2 V 0901 HEX 2305 DEC changeable 45 10 01 5 PROG01 MPEG...

Страница 13: ...PARAMETER Press ENTER to confirm B Press LEFT RIGHT to view change multiplexing output information Press ENTER to confirm Press MENU to exit 41 12 1 TS OUT PORT TS OUTPUT TO ASI Press UP DOWN to disp...

Страница 14: ...face is not in order or no input signal Please check the ASI input signal source and connecting cable It shows CH01 FIFO FULL There is some data overflow from the first input interface the signal will...

Страница 15: ...ct the output program in the program s tree click to bring new program right click program s tree to delete unwanted program change selected program s info in the list of output program s tree click A...

Отзывы: