DeltaSol
®
BS/4
Indication of collector temperature
Indicates the current collector temperature.
#/,
Collector temperature
Display range: -40 ... +260 °C
[-40 ... +500 °F]
Indication of store temperatures
Indicates the current store temperature.
s
TST : store temperature
s
TSTB : store temperature base
s
TSTT : store temperature top
s
TDIS : thermal disinfection temperature
(replaces TSTT if, during thermal disinfection, the he-
ating period DDIS is active)
434"
and
TDIS
are available in Arr = 2 only
434434"43444$)3
Store temperatures
Display range: -40 ... +260 °C
[-40 ... +500 °F]
Indication of sensors 3 and 4
Indicates the current temperature of the corresponding
additional sensor (without control function).
s
S3 : temperature sensor 3 (Arr = 1 and 3 only)
s
S4 : temperature sensor 4
33
Sensor temperatures
Display range: -40 ... +260 °C
[-40 ... +500 °F]
Indication of return temperature
If heat quantity measurement is active, the temperature at
sensor 4 is indicated as TR.
42
Return tempe rature
Display range: -40 ... +260 °C
[-40 ... +500 °F]
.OTE
S3 and S4 will only be indicated if the temperature
sensors are connected.
Initialisation
Indicates the time adjusted in
tDTO
, running backwards.
).)4
ODB initialisation active
&ILLINGTIME
Indicates the time adjusted in
T&,,
, running backwards.
&,,
ODB filling time active
Stabilisation
Indicates the time adjusted in
T34"
, running backwards.
34!"
Stabilisation
4.1 Display channels
N
OTE
The displayed values and adjustment channels
depend on which system layout, which options
and functions have been selected. Only values
and adjustment channels available for the indi-
vidual settings selected will appear in the menu.
Indication of drainback time periods
4. Channel overview