10. Locate

 

washer,

 

3x

 

springs

 

and

 

screws

 

for

 

re

installation

 

later

INSTALLATION

 

11. Place

 

washer

 

on

 

top

 

of

 

heater

 

head

 

center

 

hole

12. Place

 

3x

 

springs

 

in

 

screw

 

locations

 

top

 

of

 

heater

 

head

13. Carefully

 

align

 

heater

 

head

 

center

 

hole

 

to

 

vacuum

 

tube

 

and

 

move

 

head

 

upward

IMPORTANT!

 

WHLE

 

INSTALLING

 

HEAD

 

BE

 

CAREFUL

 

NOT

 

TO

 

BEND

 

VACUUM

 

TUBE!

14. While

 

holding

 

head

 

in

 

place,

 

carefully

 

install

 

2x

 

airflow

 

tubes

 

to

 

rear

 

pipes

IMPORTANT:

 

BLUE

BANDED

 

TUBE

 

installed

 

at

 

TOP,

 

WHITE

BANDED

 

TUBE

 

installed

 

at

 

BOTTOM

If

 

installing

 

these

 

flow

 

tubes

 

in

 

error

 

it

 

will

 

generate

 

an

 

overtemp

 

error

 

when

 

running

 

heater

 

head

15. Carefully

 

move

 

head

 

upward;

 

install

 

3x

 

mounting

 

screws

 

through

 

bottom

 

holes

 

and

 

attach

 

the

 

head

 

to

 

the

 

casting

bottom

 

(NOTE:

 

3/32”

 

hex

 

allen

 

key

 

with

 

long

 

straight

 

screwdriver

 

type

 

handle

 

is

 

preferred

 

tool

 

for

 

installation)

16. Tighten

 

all

 

3x

 

spring

loaded

 

mounting

 

screws

 

until

 

they

 

‘stop’

 

(all

 

the

 

way

 

up)

Содержание APR-HHA

Страница 1: ...or vacuum cups from heater head vacuum tube 3 Remove 6x rear screws head face cover disconnect LED 2 pin wire harness and remove cover 4 As shown manually hold air cylinder lever in down position to allow movement of the vacuum tube 5 Place finger at bottom of vacuum tube and gently lift upward to topmost up position 6 Release air cylinder lever to lock tube in up position this will help protect t...

Страница 2: ...t position it will be held in place by the 2x airflow tubes in rear 9 While holding the HHA head remove both blue banded and white banded airflow tubes from rear of head and slowly drop HHA head below vacuum tube end to remove completely IMPORTANT WHLE REMOVING HEAD BE CAREFUL NOT TO BEND VACUUM TUBE 4 pin RTD conn 3 pin POWER conn 3x access holes for HHA mount screws 3x access HHA mounting screws...

Страница 3: ...g head in place carefully install 2x airflow tubes to rear pipes IMPORTANT BLUE BANDED TUBE installed at TOP WHITE BANDED TUBE installed at BOTTOM If installing these flow tubes in error it will generate an overtemp error when running heater head 15 Carefully move head upward install 3x mounting screws through bottom holes and attach the head to the casting bottom NOTE 3 32 hex allen key with long...

Страница 4: ...hole on nozzle ring 21 Tighten nozzle lever with a slight turn using pliers 22 To adjust rotation travel pull off the lever boot and use 035 hex allen key to adjust small set screw inside lever handle when rotating the nozzle should have some slight drag and not be too loose Use small pointed instrument like pick to carefully squeeze together sides of female U shaped connector in order to make goo...

Страница 5: ...ed and bring down reflow nozzle edge to about 0 25 10 0mm above board level Switch to FINE speed and adjust to 5 10 mil or as needed Bring the head down until the reflow nozzle edges are just above board level 28 Examine all 4 sides of the reflow nozzle edges with respect to board level All 4 sides should be parallel to board level 29 If nozzle edges are not parallel or co planar adjust the 3 spri...

Страница 6: ...ftware manual mode put the vacuum tube in FREE Use a finger to lift up vacuum pipette so that it is at same approximate level as bottom nozzle edge then put the vacuum tube in LOCK old soft Down to keep pipe in place 33 Pull out the camera In COARSE mode lower the head to where the reflow nozzle bottom edge is about 1 25 4mm above the camera Be careful not to hit the camera with the nozzle or pipe...

Страница 7: ...te to accommodate each side of a full nozzle rotation 4 edges 38 After centering the vacuum pipette to the nozzle box tighten the 4 screws on the upper plate and re verify centering NOTE If the 3 spring loaded heater head screws described in Section 3 are adjusted off and nozzle is hanging too much at an angle it may not be possible to center the pipette in the box this is why it important to perf...

Страница 8: ...40 Check vacuum tube FREE function in manual mode if head is misaligned the tube may contact and scrape at the bottom grille hole edge ...

Отзывы: