75
5-2-2020
APQS.com
Daily Maintenance
Replace the bad fuse with a new one,and reinstall the fuse holder into the machine. When putting the fuse
holder back into position, metal clips should be bent away from the fuse in the holder as shown in photo
below, and when reinserting the holder into the machine, gently compress the spring just enough to get the
clips to clear the opening, but do not compress them too much or the power won't be able to transfer
through the fuse.
Using flat blade screwdriver, turn the fuse holder ¼ turn clockwise while slightly pushing in on the fuse
holder to lock it into position. Reconnect cable from top cover, and replace the covers using these
instructions in reverse.
Lock fuse into position by pushing slightly while
turning ¼ turn clockwise
Remember to reconnect cable to thread break
sensor before reinstalling cover
Fuse holder removed from
machine
Squeeze metal side clips to hold fuse in
position for reinstallation in board