background image

                                                                                                                                                               

ApPower™ 

 

picture

 

The left one in the picture is Output port: 1for anode, 2 for cathode;   
The right one is Input port: L for anode, N for cathode. 

 
Notice: When you plug an external connection to the socket, as shown in the 
schematic  wiring  polarity,  be  sure  correspond  do  not  connect  reversely,  and 
when  use  multimeters  to  measure  voltage,  do  not  put  2  multimeter  pens 
together to prevent short-circuits. 

 
 

Section VI: Suggestions 

 
1. Solar OPS best working temperature is 15

C

45

C due to cell characteristics. The 

temperature too high or too low will cause partial power cannot be released and that 
would shorten service time of load-end. 

2.  Solar  OPS  is  better  to  charge  40%

60%  of  capacity  and  keep  the  packs  in  room 

temperature storage while battery long does not use. 

3.  The  Company  is  not  responsible  for  any  accident  caused  by  operating  does  not 

comply with this manual. 

 
 
 
 
 
 
 
 

Содержание Solar Outdoor

Страница 1: ...ApPower 0 Solar Outdoor Power Supply Operation Manual Item No OPS 24120 Please read the instruction carefully before using Please keeping properly for future reference...

Страница 2: ...e manual and please pay more attention to the section of Safety Cautions The specification in this manual is subject to change without notice MANU Introduction 2 Section I Service Range and Type 3 Sec...

Страница 3: ...The copyright of the content in this manual including text and picture is owned by Array Power Cleaning Energytech Inc any individual or legal entity is not allowed to translate modify or adapt in any...

Страница 4: ...h supporting hanger provided by us shown as picture 2 The product is made by the Lithium Iron Phosphate LiFexM 1 x PyOz cells with advantages of low self discharging rate zero pollution long service l...

Страница 5: ...manual instructions strictly Section IV Technical Specifications 4 1 Basic Performance No Item Specification Remarks 4 1 1 Rated capacity 11Ah 4 1 2 Open circuit voltage 26 6 0 3VDC 4 1 3 Input Maximu...

Страница 6: ...ian as the Protection Circuit Board inside 5 5 Connecting anode and cathode with metal is extremely prohibited 5 6 No striking throwing and trampling to Solar OPS 5 7 Do not put Solar OPS in the water...

Страница 7: ...ge do not put 2 multimeter pens together to prevent short circuits Section VI Suggestions 1 Solar OPS best working temperature is 15 C 45 C due to cell characteristics The temperature too high or too...

Страница 8: ...eption from warranty as following 1 The damage from transportation packing improper operation is caused by user 2 Unauthorized dismantlement 3 Altering delivery date 4 Using larger load power than rat...

Отзывы: