background image

                                                                                                                                                               

ApPower™ 

Section III: Service Condition 

 

3.1 Solar OPS IP code is 65 grades that can be used both indoor and outdoor. 
3.2 Rated charging:    voltage: DC 28.8

30.4V current: 5A 

3.3 Rated discharging: voltage: DC 20.8

26.4V current: up to the load power, and 

the maximum load power no more than 240W. 

 
Notice

:  Solar  OPS  built-in  a  Protection  Circuit  Board  inside,  please  operate  in 

accordance with the manual instructions strictly. 

 
 

Section IV: Technical Specifications 

4.1 Basic Performance   

No. 

Item 

Specification 

Remarks 

4.1.1 

Rated capacity 

11Ah 

 

4.1.2 

Open-circuit voltage 

26.6±0.3VDC 

 

4.1.3 

Input 

Maximum charging 
current 

5A 

                 

4.1.4 

Charging voltage 

28.8

30.4VDC 

 

4.1.5 

Output 

Discharging voltage 

20.8

26.4VDC 

 

4.1.6 

Maximum   
discharging current 

10A 

 

4.1.7 

Rated voltage 

24VDC 

 

4.1.8 

Size 

Length   

346mm 

 

Width   

230mm 

 

Height   

120mm 

 

4.1.9 

Weight   

7.1±0.5kgs 

 

4.1.10 

Working 

Temperature 

charging 

0~45

 

discharging 

-20~60

 

4.1.11 

Storage 

Temperature 

Less than 1 month   

-20~50

 

Less than 6 months 

-20~30

 

           

     

 

 

 

Содержание Solar Outdoor

Страница 1: ...ApPower 0 Solar Outdoor Power Supply Operation Manual Item No OPS 24120 Please read the instruction carefully before using Please keeping properly for future reference...

Страница 2: ...e manual and please pay more attention to the section of Safety Cautions The specification in this manual is subject to change without notice MANU Introduction 2 Section I Service Range and Type 3 Sec...

Страница 3: ...The copyright of the content in this manual including text and picture is owned by Array Power Cleaning Energytech Inc any individual or legal entity is not allowed to translate modify or adapt in any...

Страница 4: ...h supporting hanger provided by us shown as picture 2 The product is made by the Lithium Iron Phosphate LiFexM 1 x PyOz cells with advantages of low self discharging rate zero pollution long service l...

Страница 5: ...manual instructions strictly Section IV Technical Specifications 4 1 Basic Performance No Item Specification Remarks 4 1 1 Rated capacity 11Ah 4 1 2 Open circuit voltage 26 6 0 3VDC 4 1 3 Input Maximu...

Страница 6: ...ian as the Protection Circuit Board inside 5 5 Connecting anode and cathode with metal is extremely prohibited 5 6 No striking throwing and trampling to Solar OPS 5 7 Do not put Solar OPS in the water...

Страница 7: ...ge do not put 2 multimeter pens together to prevent short circuits Section VI Suggestions 1 Solar OPS best working temperature is 15 C 45 C due to cell characteristics The temperature too high or too...

Страница 8: ...eption from warranty as following 1 The damage from transportation packing improper operation is caused by user 2 Unauthorized dismantlement 3 Altering delivery date 4 Using larger load power than rat...

Отзывы: