Mode Configuration Settings
Use the internal 4-position DIP switch and the J1 jumper to set
configuration modes.
SF900’s in use as switch following pair
“Transmit” side unit
“Receive” side unit
Loopback Off
Loopback Enabled
J1:
T or L
T or L
T or L
SW1
OFF (default)
OFF
ON
SW2
OFF (default)
OFF
ON
SW3
OFF (default)
OFF
ON
SW4
OFF (default)
OFF
ON
Loopback Mode: When enabled, activates the corresponding relay
at the originating (transmit) end confirming the switch change was
carried out at the receiving end. When loopback mode is enabled,
the corresponding inputs at the “receive” end are ignored.
SF900 Settings when used with SFT900-4 4-Button Remote
Control Transmitter
Switch /
Mode
Momentary
Toggle
Latched
Output
J1
T or L
T
L
SW1
OFF
ON
ON
Relay 1
SW2
OFF
ON
ON
Relay 2
SW3
OFF
ON
ON
Relay 3
SW4
OFF
ON
ON
Relay 4
Momentary:
Output is activated for only as long as button is
pressed.
Toggle:
“Push on/Push off”
Latched:
A latched mode operates with at least one other channel
set to latched mode. For example, if channel 1 and 2 are set to
latched mode, pushing button 1 on the SFT900-4 will turn relay 1
on the SF900. Pushing button 2 will turn off relay 1 and turn on
relay 2. This mode is often used when a separate on and off
button is desired. If more than 2 channels are selected for latched
mode, only 1 relay can be activated at any given time. Any
activated relay will result in the others being turned off.