CSP-CSPS-8000/B Section 1 Page 17 of 30
AC POWER REQUIREMENTS
Voltage ratings are quoted elsewhere in this manual.
TYPICAL CURRENTS
At 1500J at 1 pps (AVIP out of circuit); Non PFC charger, the following currents apply:-
Voltage
Peak Current
Average Current
110 VAC 50 Hz
56A
40A
240 VAC 50 Hz
40A
18A
(At 60 Hz, the peak currents are slightly smaller)
LINE VOLTAGE DERATING
The capability of the HV charger to deliver energy to the load (storage capacitors)
reduces with reduced line voltage as the following tables apply.
240 V Models.
Line Voltage
Charge Rate
180 VAC
2500 J/second
200 VAC
2800 J/second
210 VAC
>3000 J/second
115 V models
Line Voltage
Charge Rate
100 - 115 VAC
2600 J/second
116
– 130 VAC
>3000 J/second
You may notice that the low line voltages above are below those specified in the rear of
this manual under ‘specifications’ The above tables denote the ability of the charger to
perform under certain line voltage conditions, and not the complete system. We do not
recommend operating the CSP-S units below the minimum voltages listed in the
specification section of this manual.