CSP-CSPS-8000/B Section 1 Page 29 of 30
Safety Features
Should any fault develop, the high voltage PSU (Charger) and all capacitors (which have
bleed resistors) are individually dumped to ground, until the system is reset. A double
layer of safety cut-outs ensure that partial failure results in system shutdown.
Interlocks
: Dumps high voltage when fault develops.
Time Out
: Shut down after period (~30 seconds) without key pulse.
Local/Remote
: Disables remote (if fitted).
Load
: Shuts down HV upon open circuit load or load over current.
Reset
: Resets unit after fault or if interlock activated.
Keyswitch
: Must be rotated to enable high voltage. Switch can be
removed to disable unit for example when working on deck.
Open circuit detect
: Disables firing when an open circuit load is present.
Thermal shut-down
: HV charger shuts down if it overheats.
Options
Remote
: Allows operator to control unit at a distance. Includes key
pulse line.
Junction Box
: For connection of standard transducer cables to HV
connector.
Shock Mount Housing : For transportation and operation. (Recommended.)
Transit Case
: For storage and transportation. Foam lined.
Field Spares Kit
: For trained technicians only. For servicing units in the field.
Although correct at time of printing, these specifications are subject to change without
notice.
Содержание CSP-S 4000
Страница 2: ...CSP CSPS 8000 B Section 1 Page 2 of 30 ...
Страница 3: ...CSP CSPS 8000 B Section 1 Page 3 of 30 OPERATION MANUAL Section 1 ...
Страница 4: ...CSP CSPS 8000 B Section 1 Page 4 of 30 ...
Страница 6: ...CSP CSPS 8000 B Section 1 Page 6 of 30 ...
Страница 8: ...CSP CSPS 8000 B Section 1 Page 8 of 30 ...
Страница 10: ...CSP CSPS 8000 B Section 1 Page 10 of 30 ...