Unit Resets as Normal, HV Will Not Select
Check position of Remote/Local switch. Also:
Replace Control Board
Replace Front Panel Board
Replace Front Panel Power Selection Switch
HV Relays Operate but no EOC Lamp
Suspect HV Charger or HV BNC charger cable. Also:
Charger Power Switching Relay
Control
Board
Output
Thyristor
Storage
Capacitors
HV
Diodes
Auto Power Control Board
EOC Lamp Illuminates, but unit Will Not Discharge
Check for presence of Input Key Pulse and position of Key Polarity switch. Is key Lamp
Illuminating in unison with Input Key pulse?, if not suspect Input Key Board. Also:
Control
Board
If LED2 on Control Board is Illuminating in Conjunction with Input Key, but unit still not
discharging no load fault reported
Check Thyristor Interface board and thyristor.
Check cabling to Thyristor interface board and thyristor.
Upon discharge Load fault reported and unit shuts down
Check load for continuity.
Check load for short circuit, unit will shut down if current greater than 4500A.
EOC and HV Fault Lamp Illuminated
Open circuit on HV Charger output. Also:
Open Circuit Energy Storage Capacitor (Verify by trying alternative power setting).
HV Fault Illuminated, No EOC
HV Charger Faulty, Also:
Short Circuit Energy Storage Capacitor (Verify by trying an alternative power setting).
No Warning Lamps Illuminated, No EOC and No Output
Press Charge Rate switch, if Unit now operates then Auto Charge Control board is faulty.
Unit Fires On Alternative Key Pulses
Input Key Rate too high.