background image

 

 

 

 
 
 
 
 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1082 Smart Switch 

Firmware Version 1.12 

Operation Manual 

 

Содержание 1082

Страница 1: ...1082 Smart Switch Firmware Version 1 12 Operation Manual ...

Страница 2: ..._____________________________________________________________________________________________________ __________________________________________________________________________________________________________ Page 2 of 48 THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Страница 3: ...sion History Issue Change No Reason for change Date 11 1852 Additions for 1100 Series Beacons and Sigma2 refer to DCR note 15 08 17 10 1501 Addition to Section 3 4 1 Identified Beacon Model and Configuration Message refer to DCR note 22 07 14 9 1480 Addition to Section 3 5 1 Channel refer to DCR note Other minor amendments 13 06 14 8 1335 Minor amendments to Sections 29 05 13 7 1330 Addition to Se...

Страница 4: ...AGE 12 3 5 BEACON CONFIGURATION 14 3 5 1 CHANNEL 16 3 5 1 1 AAE CHANNEL 17 3 5 1 2 SIGMA2 QUICKSET 18 3 5 1 3 SIGMA2 CHANNEL 19 3 5 1 4 IXB CHANNEL 21 3 5 1 5 SWB QUICKSET 23 3 5 1 6 SWB CHANNEL 24 3 5 2 BATTERY 25 3 5 3 DEPTH STATUS 26 3 5 4 SERIAL NUMBER 26 3 5 5 MCU FIRMWARE VERSION 27 3 5 6 DSP FIRMWARE VERSION 27 3 6 RESPONDER TEST 28 3 7 TRICKLE CHARGE 29 3 8 FAST CHARGE 30 3 8 1 FAST CHARGE...

Страница 5: ...ethods Tel 44 0 1493 440355 Fax 44 0 1493 440720 Email techsupport appliedacoustics com Applied Acoustic Engineering Ltd has made every effort to ensure that the information contained in this manual is correct at time of print However our policy of continual product improvement means that we cannot assume liability for any errors which may occur These written instructions must be followed fully fo...

Страница 6: ... and depth telemetry transmission selection AAE 1000 1100 Series beacon fast charge activation and monitoring Compatible AAE beacon trickle charging Compatible AAE beacon responder mode testing Internal rechargeable battery Firmware field upgradeable The 1082 Smart Switch has limited compatibility with other AAE beacon ranges Refer Section 3 Smart Switch Operation for details On delivery check the...

Страница 7: ...prior to standby The L C D backlight is enabled for a brief period when any selection key is pressed The backlight can be disabled if required Refer Section 3 9 Smart Switch Configuration for details Fig 1 The L C D top line displays information or instructions for the user together with icons indicating Smart Switch operating status The L C D bottom line displays the current menu item for selecti...

Страница 8: ...ttery pack With the Smart Switch awake and operational the L C D displays a battery icon at all times representing the current internal battery charge Fig 3 Operational life is typically 2 days with constant use and with the backlight enabled Standby life is typically 5 months The Smart Switch internal battery is trickle charged at 40mA when the included 30VDC power supply unit is inserted When in...

Страница 9: ...Serial Communication The Smart Switch and a connected 1000 1100 Series beacon support RS232 serial communication at 9600 baud only Refer Section 8 Specification for serial communication specification NOTE Serial communication is only possible when a connected beacon is switched ON NOTE Serial communication is not possible when a connected beacon is fast charging Serial communication is possible wh...

Страница 10: ...s The Smart Switch menu structure has a top tier of 6 main menu options Press for next main menu option Press to select a main menu option Fig 5 Change or inspect a connected 1000 1100 Series beacon configuration Includes beacon channel beacon depth telemetry status beacon battery voltage etc Test responder function of a connected compatible AAE beacon Trickle charge a connected compatible AAE bea...

Страница 11: ...Section 3 5 for further information Press to initiate The Smart Switch will attempt serial communication with a connected beacon indicated by a Searching message to the user If a connected beacon is found the identified beacon model and channel configuration will be displayed as a scrolling message to the user Once communication has been established with a connected beacon the Smart Switch will ma...

Страница 12: ...d for beacons with MCU firmware revision 4 00 onward OPT 1 3 Options 1 and 3 are enabled in this example Contact Applied Acoustics for details Configuration CFG AAE AAE defined channel configuration including Sigma1 CFG SIGMA2 AAE Sigma2 configuration CFG IXB iXBlue IXB compatible configuration CFG SWB Sonardyne Wideband SWB compatible configuration Depending on configuration the message is comple...

Страница 13: ... in this example RC 00 Reply Code 00 in this example TAT 020ms Turn Around Time TAT 20ms in this example Sonardyne Wideband SWB Compatible Configuration QS A1 Quickset if configuration matches A1 in this example IC CIF Interrogate Channel IC CIF in this example ACA 0101 Acoustic Command Address ACA 0101 in this example TAT 062 5ms Turn Around Time TAT 62 5ms in this example Example MDL 1019D CFG A...

Страница 14: ...______________________________________________________ Page 14 of 48 3 5 Beacon Configuration Contains further sub menu options for beacon configuration Fig 7 3 5 3 3 5 2 3 5 1 3 5 4 3 5 5 Select beacon channel configuration Check or select beacon depth telemetry transmission status Check beacon battery voltage Check beacon serial number Check beacon MCU firmware version Check beacon DSP firmware ...

Страница 15: ...on except Channel if the Smart Switch is not currently communicating with a connected beacon i e is Standing by the Smart Switch will first attempt serial communication with a connected beacon indicated by a Searching message to the user If a connected beacon is found the beacon model and configuration will be identified and the selected sub menu options display updated accordingly Once communicat...

Страница 16: ...r sub menu options for channel configuration Fig 8 Press to return to previous tier menu option Channel Press for next sub menu option Press to select a sub menu option Select Sonardyne Wideband SWB compatible configuration Select Sonardyne Wideband SWB compatible Quickset scheme configuration Select AAE channel combination configuration 3 5 1 3 3 5 1 2 3 5 1 1 Select iXBlue IXB compatible configu...

Страница 17: ...ts the Smart Switch will stop communication and revert to Standing by 3 5 1 1 AAE Channel A user selection with flashing cursor highlighting one digit is displayed Fig 9 Press to return to the previous tier sub menu option AAE Channel Press to change the highlighted hexadecimal digit Press to shift the flashing cursor to highlight the next digit of the user selection Press to select the channel Th...

Страница 18: ...ct the Quickset scheme The Smart Switch will display a Waiting message followed by either a Selected message on confirmation from a connected beacon that it has configured successfully or a Failed message for the user to retry selection After a Selected message the Smart Switch will automatically return to the previous tier sub menu option SIGMA2 Qkset and re establish communication with a connect...

Страница 19: ... Turn Around Time Extension TATX in sequence before selecting the confirmed configuration Fig 11 First a user selection for Wake Up Tone WUT is displayed Press to return to the previous tier sub menu option SIGMA2 Chnl Press to change the Wake Up Tone WUT 0 through 7 Press to confirm the Wake Up Tone WUT The Smart Switch will display a Confirmed message Change Wake Up Tone WUT Confirm Wake Up Tone...

Страница 20: ...or highlighting one digit is displayed Press to return to the previous tier sub menu option SIGMA2 Chnl Valid Turn Around Time Extensions TATX are between 0ms 0000ms displayed and 9999ms in 1ms steps Press to change the highlighted decimal digit Press to shift the flashing cursor to highlight the next digit of the user selection Press to confirm the Turn Around Time Extension TATX The Smart Switch...

Страница 21: ...ate Frequency IF is displayed Press to return to the previous tier sub menu option IXB Channel Press to change the Interrogate Frequency IF 19 5kHz through 22 5kHz in 1kHz steps Press to confirm the Interrogate Frequency IF The Smart Switch will display a Confirmed message Next a user selection for Reply Code RC is displayed Press to return to the previous tier sub menu option IXB Channel Press to...

Страница 22: ... the Turn Around Time TAT is valid or Unavailable if outside limits 20ms to 200ms Finally select configuration is displayed together with a scrolling message reviewing user confirmed Interrogate Frequency IF Reply Code RC and Turn Around Time TAT Press to return to the previous tier sub menu option IXB Channel Press to select the configuration The Smart Switch will display a Waiting message follow...

Страница 23: ... scheme A1 through C3 Press to select the Quickset scheme The Smart Switch will display a Waiting message followed by either a Selected message on confirmation from a connected beacon that it has configured successfully or a Failed message for the user to retry selection After a Selected message the Smart Switch will automatically return to the previous tier sub menu option SWB Quickset and re est...

Страница 24: ...r sub menu option SWB Channel Press to change the Interrogate Channel IC CIF through MF14 Press to confirm the Interrogate Channel IC The Smart Switch will display a Confirmed message Next a user selection for Acoustic Command Address ACA with flashing cursor highlighting two digits is displayed Press to return to the previous tier sub menu option SWB Channel Press to change the highlighted decima...

Страница 25: ...annel Press to select the configuration The Smart Switch will display a Waiting message followed by either a Selected message on confirmation from a connected beacon that it has configured successfully or a Failed message for the user to retry selection After a Selected message the Smart Switch will automatically return to the previous tier sub menu option SWB Channel and re establish communicatio...

Страница 26: ...s tier sub menu option Depth Status Press to change the selection OFF disabled or ON enabled Press to select depth telemetry transmission status The Smart Switch will display a Selected message on receiving confirmation from the connected beacon that it has configured successfully NOTE Fig 16 beacon model and depth telemetry transmission status for example only NOTE For non D suffix beacons on sel...

Страница 27: ...re Version A connected beacons MCU firmware version is displayed Fig 18 Press to return to the previous tier sub menu option MCU F W Ver NOTE Fig 18 beacon model and firmware version for example only 3 5 6 DSP Firmware Version A connected beacons DSP firmware version is displayed Fig 19 Press to return to the previous tier sub menu option DSP F W Ver NOTE For non DSP version beacons the Smart Swit...

Страница 28: ...er beacon manual for compatibility and responder details Fig 20 Press to return to top tier main menu option Responder Test Press to select responder key output OFF disabled or ON enabled NOTE Fig 20 beacon model for example only If communication had been established with a connected beacon prior to selecting responder test communication will be suspended On returning to previous tier main menu th...

Страница 29: ...is not detected the Smart Switch will indicate No DC PSU Insert the 30VDC power supply to activate trickle charge ON The Smart Switch will indicate Selected The electronic switch within the Smart Switch will close and the L C D charge active icon will be displayed NOTE Serial communication with a connected beacon is stopped on selection of trickle charge menu option To re establish serial communic...

Страница 30: ... 3h21m to exit Vent beacon PRV 3 8 Fast Charge NOTE A connected beacons selector switch has a dedicated position for fast charging Refer beacon manual for details Refer Section 3 8 1 Fast Charge Activation Step 1 NOTE For fast charging Model 1060 Beacons ensure Smart Switch firmware is V1 08 or above Activate fast charging of a connected beacon Fast charge activation is controlled by an electronic...

Страница 31: ...to the dedicated fast charge position CHAR for fast charge activation to occur prompted by Step 1 Beacon to CHAR Press to confirm this Step 2 Plug in DC PSU If the Smart Switch detects the 30VDC power supply unit is already inserted Step 2 Plug in DC PSU is omitted Fast charge activation will not proceed beyond Step 2 Plug in DC PSU if the Smart Switch does not detect the 30VDC power supply unit h...

Страница 32: ... charge active icon together with elapsed time in hours and minutes Refer Fig 18 Fig 25 NOTE Fig 25 elapsed time for example only A temperature sensor embedded within the battery pack of a connected beacon is monitored by the beacons onboard fast charger If an under temperature or over temperature limit is exceeded fast charging will pause The Smart Switch displays a temperature limit has been exc...

Страница 33: ... onboard fast charger indicates battery is fully charged together with overall charge time in hours and minutes Press to exit fast charge termination display Beacon Fast Charger Fault Fig 28 Beacon onboard fast charger has detected a fault Check the following Has the beacon pressure relief valve vented Was the beacon battery pack already fully charged Attempting to recharge a fully charged battery...

Страница 34: ...tor switch set to CHAR position Is the Beacon Connection Cable secure Is the beacon battery pack open circuit Is the beacon battery pack exhausted Set the beacon to the OFF or CHAR position and trickle charge for 10 minutes before attempting to fast charge Press to exit fast charge termination display 30VDC Power Supply Unit Not Detected Fig 30 The Smart Switch does not detect the 30VDC power supp...

Страница 35: ... beacon charging time If the overall charging time exceeds a defined time limit or timeout the Smart Switch terminates beacon charging This ultimate safety feature is independent of the beacon chargers own timeout NOTE Timeout is defined automatically from a connected beacon model User Terminates Fast Charging Before Completion Fig 32 Fast charging can be terminated by the user Press to terminate ...

Страница 36: ...rt Switch Configuration Contains further sub menu options for Smart Switch configuration Fig 34 Press to return to top tier main menu option Smart Switch Press for next sub menu option Press to select a sub menu option NOTE Fig 34 beacon model for example only 3 9 1 Firmware Version The Smart Switch firmware version is displayed Fig 35 Press to return to previous tier sub menu option F W Version N...

Страница 37: ...ence if a failure occurs during a Smart Switch firmware upgrade i e a power interruption the update process can simply be repeated See Appendix C for firmware update instructions 5 Battery Replacement In due course rechargeable batteries will require replacement Return the Smart Switch to Applied Acoustic Engineering for battery replacement 6 Product Recycling Disposal Within the EU all electronic...

Страница 38: ...f the answer is yes either the battery is not charged or the Smart Switch is faulty Look for mechanical damage and also check if the connectors are damaged Try resetting the Smart Switch by depressing the reset button If there are no signs of mechanical damage try charging the Smart Switch Check the 30VDC power supply unit is operational Check the Beacon Connection Cable for damage Damage could af...

Страница 39: ...ng 9 way D socket DC Input 2 1mm DC power socket 30VDC Battery Type Internal rechargeable NiMH 4 8V Operational Life 2 days minimum constant use with backlight enabled Reverts to very low power standby after 2 minutes of no user activity Standby Life 5 months typical Charge Time 17 hours typical exhausted to full charge Charge Method Trickle charge 40mA with 30VDC power supply unit connected Altho...

Страница 40: ...fication 2 second rate output Trickle Charge 140mA maximum 27VDC 30VDC power supply unit inserted Fast Charge 1 35A maximum 30VDC 30VDC power supply unit inserted Included Accessories Beacon Connection Cable 9 way D plug to 5 way MCIL5F socket 0 5 metre Power Supply Unit 30VDC 1 2A terminated with 2 1mm DC power plug 100 250VAC mains input 1000 Series PRV Tool RS232 serial cable 9 way D socket to ...

Страница 41: ..._______________ __________________________________________________________________________________________________________ Page 41 of 48 10 Transportation by Air NiMH Battery Pack These battery packs are not classified as dangerous goods for transportation by air It is advised that any paperwork accompanying the Smart Switch state this clearly ...

Страница 42: ...___________________________________________________________________________________________________ Page 42 of 48 1 2 3 4 5 6 7 8 9 11 Appendix A Connector Details Smart Switch DC Input Socket Smart Switch 9 Way D Socket 9 WAY D SOCKET FUNCTION 2 RS232 TXD KEY PULSE 3 RS232 RXD FAST CHARGE 5 0V 9 FAST CHARGE STATUS TRICKLE CHARGE INNER OUTER 9 WAY D SOCKET FACE VIEW ...

Страница 43: ...________________________________ __________________________________________________________________________________________________________ Page 43 of 48 Beacon Connection Cable 9 WAY D PLUG MCIL5F PIGTAIL 2 1 BLACK 5 ORANGE 3 3 RED 5 2 WHITE 9 4 GREEN 5 4 3 2 1 9 8 7 6 9 WAY D PLUG FACE VIEW 1 2 3 5 4 MCIL5F PIGTAIL FACE VIEW ...

Страница 44: ..._______________________________________________________________________________________________________ __________________________________________________________________________________________________________ Page 44 of 48 12 Appendix B Quick Start Guide ...

Страница 45: ... 1082 Smart Switch PC with serial com port and Smart Switch Programmer software installed Latest version of software hhXXX ss hex RS232 serial cable 1 to 1 not crossover cable Instruction 1 Connect 1082 Smart Switch to PC com port via serial lead 2 Run SmartSwitchProgrammer exe The software will automatically start searching for a connected Smart Switch The software will automatically use the com ...

Страница 46: ... 4 Program will try to detect a connected Smart Switch and display the current firmware revision If the software does not detect a Smart Switch within approximately 15 seconds the detection will be aborted To attempt a reconnect you may press the Search button on the tool bar 5 Select Open source file and open latest firmware version hhXXX ss hex 6 Program the Smart Switch Press the Program Smart ...

Страница 47: ..._________________________________ Page 47 of 48 Click Yes to confirm programming You will be alerted if the version you are attempting to program to the Smart Switch is the same or older than the currently installed version 7 The programming will proceed The progress will be shown as below 8 When programming is complete reset the Smart Switch 9 Disconnect serial lead from Smart Switch switch on an...

Страница 48: ......