1082 Smart Switch Operation Manual
CHA-1082-8000/11
__________________________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
20
of
48
Next, a user selection for Interrogate Code (IC) is displayed. Press to return to the previous tier
sub menu option “SIGMA2 Chnl”. Press to change the Interrogate Code (IC) 00 through 15.
Press to confirm the Interrogate Code (IC). The Smart Switch will display a “Confirmed!”
message.
Next, a user selection for Reply Code (RC) with flashing cursor highlighting one digit is displayed.
Press to return to the previous tier sub menu option “SIGMA2 Chnl”. Valid Reply Codes (RC)
are between 00 and 63. Press to change the highlighted decimal digit. Press to shift the
flashing cursor to highlight the next digit of the user selection. Press to confirm the Reply Code
(RC). The Smart Switch will display a “Confirmed!” message if the Reply Code is valid or
“Unavailable!” if outside limits 00 to 63.
Next, a user selection for Turn-Around-Time Extension (TATX) with flashing cursor highlighting one
digit is displayed. Press to return to the previous tier sub menu option “SIGMA2 Chnl”. Valid
Turn-Around-Time Extensions (TATX) are between 0ms (0000ms displayed) and 9999ms in 1ms
steps. Press to change the highlighted decimal digit. Press to shift the flashing cursor to
highlight the next digit of the user selection. Press to confirm the Turn-Around-Time Extension
(TATX). The Smart Switch will display a “Confirmed!” message.
Finally, select configuration is displayed, together with a scrolling message reviewing user
confirmed Wake-Up Tone (WUT), Interrogate Code (IC), Reply Code (RC) and Turn-Around-Time
Extension (TATX). Press to return to the previous tier sub menu option “SIGMA2 Chnl”.
Press to select the configuration. The Smart Switch will display a “Waiting...” message followed
by either a “Selected!” message on confirmation from a connected beacon that it has configured
successfully, or a “Failed!” message for the user to retry selection.
After a “Selected!” message, the Smart Switch will automatically return to the previous tier sub
menu option “SIGMA2 Chnl” and re-establish communication with a connected beacon. The user
can then verify configuration from the identified beacon model and configuration message. Refer
Section 3.4.1.
NOTE: -
For 1000 series beacons, on selection the Smart Switch will display “Unavailable!” message.