1. Installation
MODELS KF15SS
Voltage 230V
Current 30A
Hi-light plate 1200W
2
Hi-light plate 1800W
1
Hi-light plate 2200/700 W
1
Max power W
6400
Installation is the buyer’s responsibility. The manufacturer accepts no liability for this service. Any action that the
manufacturer has to take due to an erroneous installation will not be covered by the guarantee.
The flush-mounted cook tops are designed for installation in work tops made of all kinds of material, providing they
can withstand a temperature of 100°C, and are between 25 and 40 mm thick. If the cook top is installed in a
position so that the side of a kitchen unit comes up against its left-hand or right-hand side, the distance between
the vertical panel and the edge of the cook top must always be at least 150 mm. The distance between the back
wall and the edge of the cook top must be at least 55 mm. A partition made of insulating material (wood or the like)
must be inserted between the cook top and the space below. This partition must be at least 10 mm from the
underside of the cook top tray.
X
= minimum 150 mm
Z
= 10 mm
Y
= partition