600840-000037 Stratus ESG Installation Instructions (Experimental)
Rev. 1.2
Last Revised: May 9, 2016
Page 14 of 52
Electrical specifications
Characteristic
Specification
Altitude
Up to 25,000 ft
External Suppression Input
Low
≤ 0.5 V
High
≥ 5 V (suppressed)
Mode A Capability
4096 Identification Codes
Mode C Altitude Capability
Parallel altitude encoder: up to 62,700 ft
Serial altitude encoder: up to 126,700 ft
Mode S Capability
Parallel altitude encoder: up to 62,700 ft
Serial altitude encoder: up to 126,700 ft
Operational Temperature Range
-20°C to +55°C
Receiver Frequency
1030 MHz
Receiver Sensitivity
-74 dBm nominal for 90% replies
Transmitter Frequency
1090 MHz ± 1 MHz
Transmitter Power
310 Watts nominal
Table 3: Electrical specifications
Power requirements
Characteristic
Specification
Input Voltage Range
11 to 36 VDC
Nominal Current Draw
0.28 A at 28 VDC
0.5 A at 14 VDC
Power Input
8 W Typical
59.5 W Max
Table 4: Power requirements
1.4.
Required tools
The following tools are needed for installation of Stratus ESG.
Tool
Part Number
Used For
3/32” hex driver
Securing locking mechanism
through the faceplate
External retaining ring pliers
RF pass through adapter
Crimp tool
M22520/2-01
DSUB pins
Positioner
M22520/2-08
DSUB pins
Insertion/Extraction tool
M81969/39-01
DSUB pins
Table 5: Required tools