![Appareo Stratus ES Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/appareo/stratus-es/stratus-es_installation-instructions-manual_2954815031.webp)
600840-000031 Stratus ES/ESG Installation Instructions
Rev. 2.2
Last Revised: February 20, 2018
Page 31 of 45
5. Functional tests
When installed in accordance with these installation instructions, Stratus ES/ESG complies with
14 CFR Part 91.227.
Final installation checks for Stratus ES/ESG are the responsibility of the installer. The installer
must ensure that Stratus ES/ESG is installed on an aircraft that coincides with the approval
given within the testing performed for the TSOs held by this device:TSO-C112e, TSO-C145d
(Stratus ESG only), and TSO-C166b. Refer to Appendix A.
After installation is complete, verify operation as identified in 14 CFR Part 43, Appendix F. The
IFR6000 with OPT3 (manufactured by Cobham AvComm – formerly Aeroflex Test Solutions) or
equivalent test set can be used to determine compliance.
Additional testing requirements can be found in Chapter 4 of Advisory Circular (AC) 20-165B.
Additional functional tests may be required.
When installed correctly, Stratus ES/ESG complies with 14 CFR Part 91.215 & 91.225. While in
airspace specified in 14 CFR Part 91.215, Stratus ES/ESG must be maintained to 14 CFR
Part 91.413. Additional maintenance information can be found in the Instructions for Continued
Airworthiness (600845-000025).
In addition to maintaining compliance to the regulations above, perform the following operational
tests after configuration.
NOTE
: Tests should be executed in an area where the aircraft has an unimpeded view of the
sky so that a proper GPS fix can be established.
5.1.
Power bus
Turn on power to the aircraft. Verify that the unit powers on.
5.2.
Discrete inputs
NOTE
: Depending on the installation, the functional tests for the following discrete inputs are
optional.
1. Turn off Stratus ES/ESG and enter into configuration mode (while holding the
FUNC
key, press and release the
PWR
key).
2. Press
FUNC
or the arrow keys to advance to the external input diagnostics screen.
The screen displays the real-time state of the external standby, external IDENT, and
squat switch inputs.