background image

VIII. MAINTENANCE

15

There are several areas of the stove and chimney system 
that will need periodic maintenance to ensure safe and 
efficient operation.
1. ASH REMOVAL 
When ashes get 3 to 4 inches deep in your firebox, wait 
until the stove has cooled, then remove the grate at the 
bottom of the heater into the ash pan below. Carefully 
remove the pan. Ashes should be placed on a non-
combustible floor or on the ground, away from all 
combustible materials pending final disposal. The ashes 
should be retained in the closed container until all 
cinders have thoroughly cooled.

NOTE: For the most efficient stove operation leave a 
minimum of 2” ash in the firebox at all times. This will 
help maintain a hot charcoal bed. 

NOTE: DO NOT OVERFIRE THIS HEATER.

Attempts to achieve heat output rates that exceed heater 
design specifications can result in permanent damage to 
the heater and to the catalytic combustor.

2. CARE OF THE GLASS
The glass supplied with your stove is designed to 
withstand extremely high temperatures. However, like 
any glass product, IT CAN BE BROKEN! Take care not 
to bump it with a log or a poker, and be sure the wood 
is entirely inside the stove before attempting to close the 
door.
Periodically opening the drafts and allowing the fire to 
burn brightly will help reduce the soot buildup on the 
glass. The glass may be cleaned with a NON-ABRASIVE  
cleaner such as a spray glass cleaner or oven cleaner. 
One of the simplest and most effective ways of cleaning 
the glass is to dip a dampened rag in the ashes and scrub 
the surface clean. The application of a non-stick cooking 
spray to the inner surface of the glass will help keep it 
clean. 

6. ACHIEVING CATALYST LIGHT OFF WHEN 
REFUELING
During the refueling and rekindling of a “charcoal 
phase” fire, operate the stove at a medium or high firing 
rate for about 10 minutes to ensure that the catalyst 
reaches approximately 600 degrees F.
It is important to periodically monitor the operation of 
the catalytic combustor to ensure that it is functioning 
properly and to determine when it needs to be replaced. 
A non-functioning combustor will result in a loss of 
heating efficiency and an increase in creosote emissions. 

3. CHIMNEY CARE
When wood is burned slowly, it produces tar and other 
organic vapors, which combine with expelled moisture 
to form creosote. The creosote vapors condense in the 
relatively cool chimney flue of a slow burning fire. As a 
result, creosote residue accumulates on the flue lining. 
The chimney connector and chimney should be 
inspected at least twice yearly during the heating season 
to determine if a creosote buildup has occurred.

If creosote has accumulated, it should be removed to 
reduce the risk of a chimney fire.

NOTE: Insert model stoves should be removed from the 
fireplace for cleaning. Slide the stove out and place it on 
a piece of cardboard or drop cloths to protect the floor. 
The fireplace and throat of the chimney CANNOT be 
properly cleaned with the stove in place.

4. STOVE FINISH 
All the stoves are finished with a specially formulated 
high temperature paint. During the first few firings of 
the stove, a slight odor of paint may be noticed. This is 
normal during the curing process and the fumes are not 
hazardous. If they should cause irritation, simply crack a 
window or door for a few minutes to disperse the fumes.

NOTE: Although non-toxic, the fumes MAY set off a 
smoke detector located near the stove.

5. BLOWER CARE
The blower should be removed and cleaned every four 
months. Unplug the blower before removing or servicing. 

TO OIL THE BLOWER:
The blower should be oiled at least two times per season 
with SAE-20. The oil ports (2) are located on the 
opposite ends of the center hub on the top side of the 
blower (see illustration - next page).

Содержание 36-BW

Страница 1: ...Appalachian s 36 BW INSTALLATION AND OPERATION PROCEDURES FIREPLACE INSERT FREESTANDING 1995 Appalachian Stove Fabricators Inc ...

Страница 2: ... VIII Maintenance 15 1 Ash Removal 15 2 Care of the Glass 15 3 Chimney Care 15 4 Stove Finish 15 5 Blower Care 15 6 Door Gasket Replacement 16 7 Motor Maintenance 16 TABLE OF CONTENTS IX Safety 16 X Limited Warranty 17 XI Warranty Registration 18 Thank you for purchasing the Model 36 BW stove Appalachian Stove welcomes you to the growing ranks of energy conscious Americans Heating with wood and bi...

Страница 3: ...increase heat extraction by controlling the escape of hot combustion gasses and smoke The sliding damper is opened by pulling the control handle out and closed by pushing the handle in 8 Draft control regulate the burning rate and the heat output of the stove The larger the fire the more heat the unit will produce The drafts are opened by pulling out the draft slide and may be left in any intermed...

Страница 4: ...of the fireplace 2 INSTALLATION AS A FREESTANDING UNIT The Model 36 BW stove must be installed with adequate clearance from combustible surfaces to assure safe operation FIGURE 2 A Composition of the wall structure combustible or non combustible materials B Type of stove pipe used to connect the stove to the chimney or flue single wall to double wall insulated pipe NOTE Walls of wood frame constru...

Страница 5: ...d the fireplace of furniture rugs etc B Place drop clothes or other protective materials on the floor and hearth to protect against damage C Remove ashes and clean the firebox floor D Remove the damper plate if possible or block it open using non combustible materials such as brick or rock E Insert the interior of the firebox and flue for possible deterioration of mortar joints loose bricks and ex...

Страница 6: ...eal firmly against the face of the fireplace compressing the insulation to accomplish a seal 5 IMPORTANCE OF PROPER DRAFT Draft is the force that moves air from the appliance up through the chimney The amount of draft in your chimney depends on the length of the chimney local geography nearby obstructions and other factors Too much draft may lead to excessive temperatures in the appliance and may ...

Страница 7: ... of the installation will simplify the process and help achieve effective operation of the unit A Select the location for the stove installation The stove should be positioned so that the air flows to the rest of the home in the most direct route possible B Locate the approximate penetration point of the chimney structure Avoid roof areas such as valleys ridges dormers and hips Place the floor pro...

Страница 8: ...al screws to prevent accidental separation C If an elbow is installed the horizontal section of the stove pipe should slope 1 4 per foot or run toward the stove to allow creosote to drip into the firebox D Always install the single wall stove pipe with the male crimped end down to prevent leakage of creosote or moisture 5 INSTALLATION INTO MASONRY FLUE Masonry flue for use with solid fuel applianc...

Страница 9: ...roof structure or 2 feet higher than the highest point within 10 whichever is greater This assures proper chimney function and reduces the possibility of back drafts NOTE All installations must meet local building and fire codes Check with local building officials for assistance in getting permits inspections and good advice 7 IMPORTANCE OF PROPER DRAFT Draft is the force that moves air from the a...

Страница 10: ... OPTIONAL BRASS BRASS FOR TRIM PANELS 1 Mount the top and side strips to the trim panels with the self tapping screws that are provided Leave approximately 1 at the top edges of the trim to be covered by corner brass If necessary strips can be easily cut with a hacksaw 2 Mount the two brass corners overlapping the top and the side brass strips 3 Remove the protective coating from the brass strips ...

Страница 11: ...e equipped with a temperature probe to monitor catalyst operation Proper functioning combustors typically maintain temperatures in excess of 500 degrees F and often reach temperatures in excess of 1000 degrees F If catalytic temperatures are not in excess of 500 degrees refer to the Catalyst Troubleshooting Guide or further information located in this manual To determine if the catalyst is working...

Страница 12: ... or the stove door is being opened too quickly Glowing stove parts may be attributed to running the stove too hot excessive amounts of wood a high draft reduce when temperatures become too excessive a glowing combustor which is normal during first 1 3 of burn cycle or a chimney fire close inlet air and outlet dampers completely if this does not help vacate home and call the fire department immedia...

Страница 13: ...st not in metal housing should be wrapped with 1 16 gasketing before installing Locate the catalysts from the front of the damper housing Reinstall the sealing D New gasketing should be installed to allow for a seal between the damper housing and the firebox top This may be done by putting a layer of gasketing around the top where the housing will be located In both cases the use of an adhesive to...

Страница 14: ...ur home comfortable CAUTION DO NOT UNPLUG YOUR BLOWER WHILE THE STOVE IS IN OPERATION VII OPERATION CAUTION THE ASH PAN DRAWER MUST BE CLOSED WHEN THE STOVE IS IN OPERATION For the best results in maintaining and achieving fewer emissions in your certified stove we have found the following instructions to be helpful in operating the 36 BW For a high or maximum burn fully open the manual draft cont...

Страница 15: ...the stove at a medium or high firing rate for about 10 minutes to ensure that the catalyst reaches approximately 600 degrees F It is important to periodically monitor the operation of the catalytic combustor to ensure that it is functioning properly and to determine when it needs to be replaced A non functioning combustor will result in a loss of heating efficiency and an increase in creosote emis...

Страница 16: ...nded as liquid types can cause problems if sprayed onto a hot stove BE SURE EVERY MEMBER OF THE FAMILY KNOWS WHERE THE EXTINGUISHER IS AND HOW TO USE IT 7 Use of a chimney cap with an approved spark arrestor is recommended 8 Use caution when loading or working around the stove to prevent burns 9 Make sure the ash pan drawer is closed when the stove is in operation WARNING THE INSTALLATION OF THIS ...

Страница 17: ...amage from handling or acts of God This warranty is in lieu of all other warranties expressed implied or statutory and the manufacturer expressly excludes any implied warranty of fitness for a particular purpose or an implied warranty of merchantability and all other obligations or liabilities of the manufacturer who neither assumes nor authorizes any person to assume for it any other obligations ...

Страница 18: ......

Страница 19: ...____________________________________ CITY __________________________________STATE ________________ HOW DID YOU HEAR ABOUT APPALACHIAN STOVE ___________ ______________________________________________________________ TYPE OF HEAT YOU PRESENTLY HAVE ________________________ APPROXIMATE SQUARE FEET OF HOME ______________________ NUMBER OF ROOMS _________________________________________ TYPE OF CONSTRU...

Отзывы: