838VHU0DQXDO
&KDSWHU 7URXEOHVKRRWLQJ
$
(UURU5HFRYHU\3URFHGXUH
To clear the errors noted in Section 5.2.1, take the following steps:
1. Power off the system.
2. Change the jumper shunts according to the error to be cleared.
3. Start the system.
4. Enter the proper parameters in SRM Console, load the Operating Sys-
tem.
5. Power off the system.
6. Restore the jumper shunts to their default positions.
7. Start the system.
Table 5-4
Diagnostics and Flash Recovery Configuration
Settings (J29)
Function
Install Jumper on Pins:
0/1
6/7
14/15
Normal Boot Sequence
(using firmware)—Default
0
0
0
Restore Factory Defaults
(Bypass password check)
0
0
1
Normal Recovery
(using firmware)
1
0
0
Alpha Diagnostics Recovery
(using firmware)
1
0
1
Interactive Alpha Diagnostics
(using operator console)
1
1
0
Interactive Alpha Diagnostics
(using Debug Port J42/J43)
1
1
1
Interactive Reset PAL Code
(using Debug Port J42/J43)
0
1
0
Notes: 1. 0 = No shunt installed.
1 = Shunt installed.
2. The Debug Ports (primary Alpha Slot B Module port J43 and secondary Alpha
Slot B Module port J42) default to 9600 baud. When using the Interactive
Reset PAL code function, type an uppercase
U
to set the interactive baud rate
higher.