The show memory command displays information about each memory
bank: slot number, size in megabytes, and the starting address. The syntax
is:
show memory
Example 4-4 Show Memory Command
P00>>>show memory
Array # Size Base Addr
------- ---------- ---------
0 512 MB 000000000
Total Bad Pages = 0
Total Good Memory = 512 MBytes
VKRZSDO
The show pal command displays the versions of PALcode. PALcode is the
Privileged Architecture Library (PAL) code, written to support Alpha
processors. It implements architecturally defined processor behavior. The
syntax is:
show pal
Example 4-5 Show PAL Command
P00>>>show pal
pal OpenVMS PALcode V1.61-49, Tru64 UNIX PALcode
V1.54-50
VKRZSRZHU
The show power command displays status information about the power
supplies, system fans, CPU fans, and temperature. This command is
useful for displaying the error state of a system that shuts down because of
a fan, temperature, or power supply failure. If the system can be restarted,
use this command. The syntax is:
show power
Example 4-6 Show Power Command
P00>>> show power
Status
Power Supply
good
CPU 0 Power
good
CPU 1 Power
good