VBL Series
Rev. A2, 9/09
16
Automation Products Group, Inc.
APG...Providing tailored solutions for measurement applications
Tel: 1/888/525-7300 • Fax: 1/435/753-7490 • www.apgsensors.com • [email protected]
• Sensitivity
The sensitivity can be adjusted by using the sensitivity switch and by
adjusting the voltage.
H with 4.5~5.5 VDC: for highly fluidized materials.
L with 2.0~3.0 VDC: for light materials.
L with 4.5~5.5 VDC: standard adjustment (bulk density 0.2/cm
3
or more)
L with 6.0~7.0 VDC: for sticky materials.
Set the sensitivity switch to AJ.
Turn sensitivity volume until the desired voltage is read.
After adjustment, set the switch to H or L and make sure 8~10 VDC can be
read.