Model Number Configurator

Part Number: PT-500_____ - _____ - _____ - _____ - _____ - _____ - _____ - _____
 

            

A         B          C         D          E          F       G    H

 

A. Cable Type

 

□ 

-

    Urethane - Blue (with vent tube)

 A

  

PVC - Black (no vent tube - sealed unit) 

 B

  

Hytrel .31” Ø - Black (with vent tube)

 

 C

  

PVC - Black (with vent tube)

 

 D

  

Hytrel .25” Ø - Black (with vent tube)

B. Pressure Range

 

Specify range in desired unit of measure

__________

                 

Max Water Depth

   

 

       462.2 ft. (140.9 m), 300 psig

C. Standard Units of Measure

 

PSI

 

FTH2O

 

INWC

 

INH2O

 

MMH2O

 

FWC

D. Output

 

L1

  4-20 mA, 2-wire

 L3

  0-5V, 4-wire*

 L9

  10 mV/V, 4-wire*

 L10

  0-10V, 4-wire*

 

L5

  Modbus RTU, 4-wire RS-485*

 

Pressure reading only

 

 L31

  Modbus RTU, 4-wire RS-485 *

 

Level calculations, tank volume 

 

E. NPTM

 E0

  1/2” NPTM fitting for conduit,with pigtail

 E5

 

Pigtail without conduit connection 

F. Process Connection

 P1

  1/2” NPTM with removable plastic nose cone

 P5

  1/4” NPTF

 P37

  Welded Cage (anti-snag 1 piece fitting)

 P38

  1-1/2” tri-clover with 3/4” diaphragm

 P39

  Reusable Cage (includes P38 fitting) 

G. Cable Length

 (specify length of cable needed in feet)

H. Accuracy

 N0

  ±0.25%

 N1

  ±0.25% with NIST certification

 N2

  ±0.1% with NIST certification 

Note: 

Indicates this option is standard.

Note: *Indicates this option does not yet have CSA

 

 

Approvals.

Содержание PT-500 Series

Страница 1: ...APG R Doc 9002823 Rev C6 08 16 PT 500 Analog Output Series User Manual 4 20 mA 0 5 VDC 0 10 VDC mV V ...

Страница 2: ...4 Electrical Installation 5 Removal Instructions 5 Chapter 3 Maintenance 5 General Care 5 Zero Adjust 6 Vent Tube Drying 6 Repair and Returns 7 Chapter 4 Hazardous Location Installation and Certification 8 Intrinsically Safe Wiring Diagram 8 Non Incendive Wiring Diagrams 9 CSA Certificate of Compliance 10 13 NOTE Wiring and CSA Certification information in this User Manual is specific to the Analo...

Страница 3: ...pinout table Please ensure that the part number and pinout table on your label match your order The following electrical ratings and approvals are also listed on the label Please refer to the Certificate of Compliance at the back of this manual for further details IMPORTANT Your 4 20 mA PT 500 MUST be installed according to drawing 9002803 Intrinsically Safe Wiring Diagram or Non Incendive Wiring ...

Страница 4: ...material and workmanship under normal use and service of the product for 24 months For a full explanation of our Warranty please visit https www apgsensors com about us terms conditions Contact Technical Support to recieve a Return Material Authorization before shipping your product back Scan the QR code below to read the full explanation of our Warranty on your tablet or smartphone ...

Страница 5: ...PT 500 with Removable Plastic Nose Cone PT 500 with Tri clover Sanitary Fitting 88 9mm ø3 50 REMOVABLE SENSOR CAGE ASSEMBLY 7 14 181 3mm 2 00 50 8 6 44 163 5mm ø 188 THRU PROTECTIVE CONE 25 4mm ø1 00 1 1 2 SANITARY FITTING 50 3mm ø1 98 5 29 134 4mm 7 40 187 9mm 2 24 56 9mm ø3 50 88 9mm NON REMOVABLE SENSOR CAGE ASSEMBLY PT 500 with Welded Anti snag Cage ...

Страница 6: ...ft 140 88 m 300 psig Electrical Supply Voltage at sensor 4 20 mA 9 28 VDC 0 10 VDC 14 28 VDC 0 5 VDC 9 28 VDC mV V 10 VDC Output Signal 21 C 3 30 mA max Protection Reverse Polarity and Surge per IEC 61000 4 5 Load Limitation R max Vs 12V 0 02A 0 042Ω per ft of cable Startup Time 4 20 mA 100 ms 0 10 VDC 300 ms 0 5 VDC 300 ms Current Draw 4 20 mA 3 30 mA 0 10 VDC 3 mA 0 5 VDC 3 mA Materials of Const...

Страница 7: ...2O MMH2O FWC D Output L1 4 20 mA 2 wire L3 0 5V 4 wire L9 10 mV V 4 wire L10 0 10V 4 wire L5 Modbus RTU 4 wire RS 485 Pressure reading only L31 Modbus RTU 4 wire RS 485 Level calculations tank volume E NPTM E0 1 2 NPTM fitting for conduit with pigtail E5 Pigtail without conduit connection F Process Connection P1 1 2 NPTM with removable plastic nose cone P5 1 4 NPTF P37 Welded Cage anti snag 1 piec...

Страница 8: ...f the threads so it does not unravel as you screw the sensor into place Unraveling can cause uneven distribution and seal failure For straight threads use an o ring Always start screwing in your sensor by hand to avoid cross threading Thread failure can be a problem if you damage threads by over tightening them or by crossing threads For suspension mounting the PT 500 drill a 3 16 hole into the 1 ...

Страница 9: ...re in the line could result in injury or death Your PT 500 series pressure transmitter is very low maintenance and will need little care as long as it is installed correctly However in general you should For process connected sensors keep the transmitter and the area around it generally clean Avoid applications for which the transmitter was not designed such as extreme temperatures contact with in...

Страница 10: ...atically adjust to changes in barometric pressure We recom mend that PT 500A transmitters be zeroed upon receipt and after major weather events Condensation in the vent tube can damage the electronics in your sensor resulting in unreliable readings APG offers two methods of preventing vent tube condensation a venting cap and a desiccant drying cartridge The venting cap is a PVC tube with a hydroph...

Страница 11: ...ne chat at www apgsensors com Please have your PT 500 s part number and serial number available See Warranty and Warranty Restrictions for more information Repair and Returns Figure 3 4 NOTE Desiccant crystals change from blue to pink as they become saturated Car tridge must be replaced when all crystals have saturated Figure 3 3 IMPORTANT Do NOT use desiccant cartridge in the presence of vapors o...

Страница 12: ...8 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Chapter 4 Hazardous Location Installation and Certification Intrinsically Safe Wiring Diagram ...

Страница 13: ...9 Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com Non Incendive Wiring Diagram ...

Страница 14: ...thout either indicator for Canada only Eshwar Kashyap Issued by Eshwar Kashyap PRODUCTS CLASS 2258 03 PROCESS CONTROL EQUIPMENT Intrinsically Safe and Non Incendive Systems For Hazardous Locations CLASS 2258 83 PROCESS CONTROL EQUIPMENT Intrinsically Safe and Non Incendive Systems For Hazardous Locations Certified to U S Standards Class I Div 2 Groups C and D Class I Zone 2 Group IIB Ex nL IIB T4 ...

Страница 15: ...T 500 xxxx Pressure Transmitter Rated 10 28VDC 4 20mA Maximum Ambient 85 C Temperature Code T4 Maximum Working Pressure 10 000 PSI Non Incendive with the following Entity Parameters Vmax Ui 28V Imax Ii 110mA Pmax Pi 0 77W Ci 0µF Li 0µH Notes for Models PT 400 PT 500 1 The x in the Model designations may be any alpha numeric character to denote minor mechanical options not affecting safety 2 These ...

Страница 16: ...ximum Working Pressure 10 000 PSI Installed as per Drawing 9002794 Ambient Range 40 C to 85 C Enclosure type IP65 Intrinsically safe with the following entity parameters Vmax Ui 28V Imax Ii 110mA Pmax Pi 0 77W Ci 0 055µF Li 7 95µH Model PT 500 xxxx Pressure Transmitter Maximum Ambient 85 C Temperature Code T4 Maximum Working Pressure 10 000 PSI Entity parameters as follows Vmax Ui 28V Imax Ii 110m...

Страница 17: ...tection by intrinsic safety i CAN CSA C22 2 No 60079 15 12 Electrical apparatus for explosive gas atmospheres Part 15 Construction test and marking of type of protection n electrical apparatus CAN CSA C22 2 No 60529 05 Degrees of protection provided by enclosures IP Code UL 508 17th Edition Industrial Control Equipment UL 913 7Th Edition Intrinsically Safe Apparatus and Associated Apparatus for us...

Страница 18: ...Automation Products Group Inc Tel 1 888 525 7300 Fax 1 435 753 7490 www apgsensors com sales apgsensors com APG R ...

Отзывы: