background image

 

 
DIGITAL MANAGEMENT SYSTEM  DMS26   

   

10  

 

OPERATION 

 

Starting up 

The unit will energise as soon as power is applied to the IEC inlet; there is no power switch. During the start up process 
the firmware application model number and version numbers are displayed and the outputs are muted until the unit has 
completed its internal checks. Once the start-up routines are complete and the unit is ready to pass audio. The DSP 
signal path will be restored to the current settings when it was last powered down and the audio signal is gradually 
ramped up to its correct level. 
 

Selecting a Factory Preset 

The APG Digital series processors have a library of Factory Presets designed to suit a range of applications. 
Factory Presets contain some parameters that are fixed and hidden from view; the remainder of the DSP parameters are 
available for user manipulation. The number and type of hidden parameters is dependant on the Factory Preset, typically 
crossover frequencies, output delay and some EQ’s are hidden; those settings that are a function of the loudspeaker 
cabinet design and should not require adjustment for different applications. 
To recall a Factory Preset for a particular cabinet or system, press Recall and use the left hand parameter knob A to 
scroll through the available Factory Preset locations (as indicated bu a box symbol after the preset number). Once the 
appropriate preset has been selected press recall again, at which point you will be asked to confirm the action by 
pressing recall for a third time. This is to guard against accidental recall of presets. 
Factory Presets are locked so they cannot be over-written. The user can, however, store an edited version of a Factory 
Preset in any free preset location. 
Details of all the Factory Presets including output designations can be found in Appendix A. 
 

Creating a Crossover 

In addition to the Factory Presets the unit has two further ‘Base Presets’; mono and stereo. These Base Presets are 
stored in locations 1 and 2 respectively, they can be used to develop settings for any loudspeaker combination and are 
recalled in the same way as the Factory Presets described above. These presets are also locked but the user can name 
and store their own edited versions in any free preset location. 
 

Navigation and Viewing Parameters 

Many of the processing elements in each input and output path have features that may be controlled by the user, such as 
gain, frequency or limiter threshold. We call these adjustable features parameters. 
 

 

 
 
A parameter may be adjusted when it is displayed by turning one of the three-parameter knobs. Each of the three-
parameter knobs is associated with a zone on the display. Adjusting the leftmost parameter knob will change the value of 
the parameter showing in the leftmost zone of the display and so on. Turn a knob clockwise to increase the value of a 
parameter, or anti-clockwise to decrease it. The knobs are velocity-sensitive so turning a knob rapidly will cause the 
action to ‘accelerate’, so the value changes more rapidly. 
 

Содержание DMS26

Страница 1: ...USER GUIDE DIGITAL MANAGEMENT SYSTEM PROCESSOR DMS26...

Страница 2: ......

Страница 3: ...DIGITAL MANAGEMENT SYSTEM DMS26 1 APG FRANCE User Guide Digital Management System APG DMS26 Version 1 0 Ao t 2006...

Страница 4: ...call 12 Preset Store 12 DSP PROCESSING LAYOUT 13 Input DSP block diagram 13 Output DSP block diagram 13 Stereo Mono Formats 13 DSP processing Input Channels 14 Gain 14 Delay 14 High Pass Filter 14 Par...

Страница 5: ...e the flow of air through the ventilation openings Heat The appliance should be situated away from heat sources such as radiators heat registers stoves or other appliances including amplifiers that pr...

Страница 6: ...e the value of a parameter turning anti clockwise will decrease it Turning a knob rapidly will cause the action to accelerate so the value changes more rapidly Mute Buttons The LEDs next to the mute b...

Страница 7: ...ton to go to the selected output Use the Parameter button to go to the source function Choose source with the first knob which offers possibility between the Inp_A Inp_B Sum_A B with dedicated softwar...

Страница 8: ...not remove covers There are no user serviceable parts inside please refer servicing to qualified service personnel This equipment must be earthed Protect the power cord from being walked on or pinched...

Страница 9: ...tem in multi diffusion APG with or without subwoofer Digital delay Egalization for APG loudspeakers Area management signal distribution Specifications Bandwidth 10 Hz 40 kHz Dynamic 112 dB High pass F...

Страница 10: ...means both input A and B parameters The name of the output will be shown briefly at the top of the display when stepping onto an output 4 Edit Select Buttons The currently selected edit parameter pag...

Страница 11: ...ns If an unbalanced source is used a connection should be made between the pin 3 cold signal and the ground connection of the unbalanced source 13 Audio Output Connectors The processed outputs are imp...

Страница 12: ...ess recall again at which point you will be asked to confirm the action by pressing recall for a third time This is to guard against accidental recall of presets Factory Presets are locked so they can...

Страница 13: ...ages of parameters available for each channel The currently selected page is shown in the bottom left hand corner of the display this is omitted on some pages where the function is obvious The screen...

Страница 14: ...edom to adjust any or all of the parameters Factory Presets can be used as the basis for user Presets but they have some parameters that are predefined as a function of the loudspeaker system These pa...

Страница 15: ...applications There are two Formats Mono or Stereo With the Mono format all outputs have unique parameter settings and all outputs are identical in terms of processing functions and routing capability...

Страница 16: ...y parameter is adjustable in fine steps at low values the adjustment becomes progressively coarser as the value increases The velocity sensitive Parameter Knobs therefore provide accurate setting of d...

Страница 17: ...ecomes progressively steeper rather than following a linear slope so a dB octave description is not accurate Parametric Equalisation Eight sections of equalisation are provided two shelving filters an...

Страница 18: ...lectable normal or reversed with reference to other outputs Delay Knob A Adjustable in variable steps from 0 to 80ms As for input delay velocity sensitive Parameter Knobs provide finer adjustment at l...

Страница 19: ...ion is not accurate Parametric Equalisation Eight sections of equalisation are provided in a similar format to the input channel equalisation two shelving filters and six parametric Knob A Frequency 1...

Страница 20: ...d on each output Threshold is user adjustable all other parameters are carefully calculated dependant on configuration to provide clean and effective control of signal dynamics Routing Knob A Output s...

Страница 21: ...he screen contrast utility control sets the base contrast of the screen and also allows optimization for a given viewing angle Parametric equalisation width parameters can be displayed in either Q or...

Страница 22: ...10 3 1 10 4 36 30 24 18 12 6 0 6 6dB Oct 12dB Oct 18dB Oct 24dB Oct 48dB Oct Butterworth Frequency Hz M a g n i t u d e d B Linkwitz Riley 100 1 10 3 1 10 4 36 30 24 18 12 6 0 6 12dB Oct 24dB Oct 48d...

Страница 23: ...sel 100 1 10 3 1 10 4 36 30 24 18 12 6 0 6 12dB Oct 24dB Oct Bessel Frequency Hz M a g n i t u d e d B Hardman 100 1 10 3 1 10 4 36 30 24 18 12 6 0 6 4th Order 8th Order Hardman Frequency Hz M a g n i...

Страница 24: ...10 5 0 5 10 15 Low shelf varying Gain High shelf varying Slope Shelving EQ Frequency Hz M a g n i t u d e d B Parametrics Filters 100 1 10 3 1 10 4 15 10 5 0 5 10 15 Varying Gain Varying Bandwidth Pa...

Страница 25: ...put Ch Source Input A Input B and SUM HP filter frequency Off 10 Hz to 25 4 kHz 1 36 d octave steps LP filter frequency 10 Hz to 25 4 kHz and Off 1 36 d octave steps LP HP filter type 12 18 and 24 dB...

Страница 26: ...RECALL SHEET...

Страница 27: ......

Страница 28: ...APG FRANCE 19 Bis Rue des Ecoles Site Valnor ZI Haute 95500 Le Thillay RCS Pontoise 451 935 084 Tel 33 0 1 30 18 92 70 Fax 33 0 1 30 18 92 71 E mail contact apg tm fr Site www apg tm fr...

Отзывы: