69
E Z Sander
EZ3760M460-3(170328)
VFD PARAMETER
TABLES
2018-02-22
Leo
PARAM
SETTING
PARAMETER DESCRIPTION
FEED VFD
P199
3
RESET TO 60HZ DEFAULTS SETTINGS
VFD-2
P100
1
START/STOP FROM TERMINAL STRIP
AC TECH
P101
1
0-10VDC SPEED REFERENCE
SMV
P103
80
MAX FREQ
OUT PUT
P104
6.0
ACCEL TIME
3/PE AC
P105
1.0
DECEL TIME
0-400/460V
P108
58
(MOTOR AMPS / VFD RATED OUTPUT AMPS ) X 100
%
2.4/2.1A
P111
2
RAMP TO STOP
0.75KW/1HP
P121
13
TB-13A INPUT FUNCTION
0-500HZ
P140
3
RELAY IS ENERGIZED WHEB DRIVE IS NOT
FAULTED
10-30 FPM
P160
22
MIN FREQ AT 0V POT INPUT
60:1
P161
67
MAX FREQ AT 10V POT INPUT
95mm
1800RPM
MOTOR
P170
5.6
(1800 - NAMEPLATE SPEED / 1800) x 100 = SLIP (%)