9. Other Functions & Parameters 

Indication of 

calibration points 

 

Auto Power-

off 

Power-off in 8 

minutes if no 

operation 

Indication of stable 

measurements 

 

Waterproof 

level 

IP67, floats on water 

Self-Diagnosis 

information 

Er1, Er2 

Power Supply 

AAA batteries*4 

Low battery 

reminder 

           Flashes to 

remind to replace 

batteries 

Battery Life 

1000 hours 

Dimensions/Weight 

Instrument: 40*31*178mm/107g; Carrying case: 

190*165*140mm/438g 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Salt2

Страница 1: ...Salt20 Pocket Salinity Tester Instruction Manual APERA INSTRUMENTS LLC www aperainst com v1 2 ...

Страница 2: ...trical conductivity NaCl Concentration It does not measure absolute salinity 2 Keypad Functions Short press 2 seconds Long press 2 seconds 1 Short press to turn on long press to turn off 2 When turned off long press to enter setup 3 In mode setting short press to change parameter 1 When turned on long press to enter calibration mode 2 In calibration mode short press to confirm calibration 3 In mod...

Страница 3: ...n solution Stir gently leave it to stand LCD displays short press to complete 1 point calibration The tester returns to measuring mode and calibration icon appears at the button left of LCD 5 Salinity Measurement 5 1 Short press to turn on tester Rinse probe in distilled water and dry it 5 2 Stir probe in the sample solution gently leave it to stand Get readings after the smile icon comes up and s...

Страница 4: ...brated after manufacture Usually users can use the tester right away or test it in the calibration solutions to test its accuracy When error is large calibrate it before using 7 Parameter Setting 7 1 Parameter setting reference chart Symbol Parameter Setting content Code Factory Default P1 Select salinity unit ppt mg L ppt P2 Restore to factory default No Yes No 7 2 How to setup parameters When tu...

Страница 5: ... values When meter s calibration or measurement performs abnormally this function can be adopted so the meter goes back to factory default setting and then users can conduct calibration or take measurements again 8 Technical Specifications Salinity Range 0 10 00 ppt Resolution 0 01 ppt Accuracy 1 F S Calibration points 1 point auto calibration Automatic Temp Compensation 0 50 C Temp Range 0 50 C R...

Страница 6: ... operation Indication of stable measurements Waterproof level IP67 floats on water Self Diagnosis information Er1 Er2 Power Supply AAA batteries 4 Low battery reminder Flashes to remind to replace batteries Battery Life 1000 hours Dimensions Weight Instrument 40 31 178mm 107g Carrying case 190 165 140mm 438g ...

Страница 7: ...month limited warranty applies to probes This warranty does not apply to defects resulting from actions such as misuse violation of the instructions in this manual or operations in the manner not specified in this manual improper maintenance and unauthorized repairs Warranty period is the time limit to provide free service for the products purchased by customers not the service life of the tester ...

Страница 8: ...APERA INSTRUMENTS LLC Address 6656 Busch Blvd Columbus Ohio 43229 Tel 1 614 285 3080 Email info aperainst com Website www aperainst com ...

Отзывы: