9
INSTALLATION
instructions provided must install the appliance. The
manufacturer declines all responsibility for improper
installation, which may harm persons and animals and
damage property.
CAUTION
The power supply to the appliance must be switched
off before any adjustments or maintenance work is
undertaken.
INSTALLATION OF GAS HOB
WARNING
Good ventilation is required around the appliance for
easier dissipation of heat and low power consumption.
The gap between the hob and any cooker hood above it
should be at least 750mm.
The gap between the hob and any adjacent wall cabinet
above should be at least 450mm.
ELECTRICAL CONNECTION
All installation work must be carried out by a competent
Before connecting the mains supply ensure that the
mains voltage corresponds to the voltage on the rating
plate inside the cooker hood.
WARNING:
THIS APPLIANCE MUST BE EARTHED.
Mains Supply could be connected to the Mains Voltage
by Direct Connection
WARNING
Make sure the fused spur outlet is
located in an accessible position.
DIRECT CONNECTION
If the appliance is being connected
directly to the mains an omnipolar
circuit-breaker must be installed with a minimum
opening of 3mm between contacts.
If the cable is damaged or to be replaced, the operation
dedicated tools to avoid any accidents.
The installer must ensure that the correct electrical
connection has been made and that it complies with
wiring diagram.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced by
authorized technicians only.
ELECTRICAL REQUIREMENTS
Any permanent electrical installation must comply with
the latest I.E.E. Regulations and local electricity company
contractor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC)
should undertake the electrical installation.
Electrical Connection
Before connecting the mains supply ensure that the
mains voltage corresponds to the voltage on the rating
plate inside the appliance.
WARNING:
THIS APPLIANCE MUST BE EARTHED
The appliance is supplied with a 3-core mains cable and
must be connected to the electricity supply via a double
pole switch having a 3mm minimum contact gap on each
connector.
FUSE
USE A 3 AMP FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
ON
75mm
At least
300mm
750mm
At least
300mm
450mm
At least
300mm
750mm
At least
300mm
450mm