10
INSTALLATION
AGHD90GG
Cut out worktop to the template dimensions with suitable
equipment and seal the cut edge with appropriate sealant
Stretch out the supplied seal along the underside edge of
the hob, ensuring the ends overlap.
Drop the hob into position.
Secure with brackets
SILICONE
[seal]
[screw]
30mm
40mm
[bracket]
[screw]
[bracket]
VENTILATION
All rooms require a window or equivalent (e.g. a door)
which can be opened. Some rooms require a permanent
vent or extractor in addition to a window (see below).
This unit must not be used in a room which is less than
5m³. The following table details the requirements based
on the kitchen volume (L x W x H) in m³.
The above requirements also allow use of a gas oven and
grill but if there are any other fuel burning appliances
in the same room, consult the relevant British Standard
(BS5440) or Gas Safe manual.
Room Volume (m
3
)
Air vent required (cm
3
)
5
100
6 to 10
50
6 to 11
No permanent vent
required if a door opens to
the outside
11 or more
None required
The above requirements also allow use of a gas oven and
grill but if there are any other fuel burning appliances
in the same room, consult the relevant British Standard
(BS440) or Gas Safe document.
WHAT YOU SHOULD DO IF YOU SMELL GAS?
Switch off the gas supply
Open doors and windows
Call Transco 0800 111 999
THE APPLIANCE IS NOW READY TO USE.