12
INSTALLATION
CURVA60/70/90, CURVA60/70/90BK
THE APPLIANCE IS NOW READY TO USE.
ELECTRICAL REQUIREMENTS
Any permanent electrical installation must comply with
the latest I.E.E. Regulations and local electricity company
contractor who is on the roll of the National Inspection
Council for Electrical Installation Contracting (NICEIC)
should undertake the electrical installation.
ELECTRICAL CONNECTION
Before connecting the mains supply ensure that the mains
voltage corresponds to the voltage on the rating plate
inside the appliance.
WARNING: THIS APPLIANCE MUST BE EARTHED
The appliance is supplied with a 3-core mains cable and
must be connected to the electricity supply via a double
pole switch having a 3mm minimum contact gap on each
connector.
A Switched Fused Connection Unit to BS 1363 Part 4 is
recommended.
The fuse must be rated at 3 Amps.
The wires in the mains lead are coloured in accordance
with the following code:
Brown = L - Live
Blue = N - Neutral
Green and Yellow = - Earth
The connection point must be placed in a position adjacent
to the appliance so as to be readily accessible for an
engineer in the event of a breakdown.
Disconnect the appliance from the mains supply before
carrying out any kind of maintenance or cleaning.