APCO
388 Grant Street, SE, Atlanta, Georgia USA 30312-2227 Telephone (404) 688-9000 www.apcosigns.com
IS309
APCO
388 Grant Street, SE, Atlanta, Georgia USA 30312-2227 Telephone (404) 688-9000 www.apcosigns.com
IS309
06/28/01
Visuline
®
2300 Series
Non-Illuminated Display System
Preparing to Install
06/28/01
Visuline
®
2300 Series
Non-Illuminated Display System
Reassembly
Surface mounted modules utilizing the standard 2-3/4” thick
Visuline cabinet (2300.3 Series), do not require preparation and
are ready for installation.
For surface mounted modules utilizing the 3-1/2” deep LP
cabinet (2300.3LP Series), proceed with the following
instructions.
Open Door
To access the internal mounting structure, the door must first
be opened. Units with optional door locks will have specific
instructions applied to door face.
Dual Lock
is an aggressive snap-locking device used with all
door shapes. The door must be grasped at two positions as
near as possible to the corners opposite the hinge side. (Refer
to labels applied to door face.)
IMPORTANT: DO NOT attempt to open door by pulling only
one corner as this could cause glass breakage or other door
damage.
APCO Concealed Lock Option
is a spring-loaded locking device
hidden beneath the door frame. A special Concealed Lock Key
is used to unlatch the door. (Refer to labels on door.)
Conventional Keyed Lock Option
is either a plunger or camlock
device which uses a common-type key. (Refer to labels on
door.)
Side Hinged Doors:
Side hinged doors do not require door supports and must be
held open while unit is laying flat. Exercise care not to "spring"
the door by allowing it to open beyond 90 degrees.
Top Hinged Doors:
Smaller top hinged doors are equipped with support rods which
pivot away from the cabinet to mate with a notch provided on
backside of door frame. Care must be taken not to dislodge the
rod(s) when door is open.
Larger and Heavier top hinged doors are equipped with gas
cylinder “assists”. Keyed locks assure door remains closed. See
Figure 3.
CAUTION: When cabinet is equipped with gas cylinder
“assists”, maintain pressure against door and use extreme
care when opening. (See labels on door.)
Reassembly
1.
Re-insert display panel/insert(s).
Before closing door, ensure the following;
Side Hinged Doors:
- Exercise care not to "spring" the hinge by allowing the
door to swing open beyond 90 degrees.
- DO NOT exert downward pressure on an open door.
Top Hinged Doors:
- Ensure safety ribbons are secured to backside of door
frame.
- Disengage and relocate prop-rods if applicable.
- For doors with gas cylinder “assists”, apply even
pressure to both ends while closing. DO NOT close by
pushing on any one corner as this may distort the glass
and possibly cause glass breakage.
2.
Close and press door frame firmly. There should be an
audible “click” as a result of the Dual Lock fasteners
being engaged. If door fails to function properly, refer to
Trouble Shooting Guide in this section.
3.
Remove remaining protective wrappings.
4.
Forward printed Maintenance Instructions to facility
manager. For top hinged units, store padded corner
guards and safety pylons for future servicing.
Lift Door &
Disengage
Prop-Rods
Secure Safety
Ribbons
Close Door &
Listen For
Audible “Click”
Secure Safety
Ribbons
Close Door &
Listen For
Audible “Click”
NEVER LEAVE DOOR OPEN
WHILE UNATTENDED !
Do Not Exert
Downward Pressure
on Open Door
Side Hinged Doors
Top Hinged Doors
Prop-Rod Door Support
Top Hinged Doors
Gas Cylinder Door Support
Smaller Top Hinged Doors
2
Position
Prop Rod
1
Lift
Door
Larger and Heavier Top Hinged Doors
2
Unlock
Door
1
Maintain
Downward
Pressure
3
Control
Opening
Pressure
Grasp & Pull
Door Here
To Open
Grasp & Pull
Door Here
To Open
Directory
Latch
• Insert Special APCO Key into
reveal behind door frame and
slide spring-loaded latch
approx. 1/4"
• While latch is disengaged, lift
door open.
UNLOCK HERE
Glass
1/98
LB308
To Disengage Lock, insert key
into Lock and rotate clockwise,
1/4 turn. Plunger sticks out when
unlocked.
Do Not force key past 1/4 turn.
To Lock, push plunger all the
way in.
Directory
Lock
UNLOCK HERE
LB309
Door is Unlocked
When Plunger
Comes Out
Glass
1/98
Conventional Keyed Lock Operation
Concealed Lock Operation
Open Door From Two Points