PM1122-INT DIGITAL INTERFACE REMOTE
WWW.APART-AUDIO.COM / [email protected]
MICLVL:
Microphone
Master
Level
SELECT:
Input
Source
Selection
MINMSC:
Minimum
Music
Level
MAXMSC:
Maximum
Music
Level
MINMIC:
Minimum
Microphone
Level
MAXMIC:
Maximum
Microphone
Level
To
be
complete,
there
is
also
a
RSRFFU:
which
has
no
function
but
is
foreseen
for
future
use
Except
for
“SELECT”,
all
controls
can
be
used
with
following
commands:
SET,
GET,
INC,
DEC.
“SELECT”
can
only
be
used
with
SET
and
GET.
After
the
attribute,
the
zone
needs
to
be
specified,
this
can
be
ZONE1
or
ZONE2.
SET
commands
must
contain
a
value
which
is
a
number
between
0
and
100.
For
SELECT
this
is
A,
B,
C
or
D.
The
INC
and
DEC
command
will
increase
or
decrease
by
one
if
no
value
is
specified.
Settings
Unless
otherwise
stated,
settings
can
only
be
used
with
the
SET
command
and
will
only
have
ON
or
OFF
as
possible
value.
The
first
3
settings
are
available
to
ease
the
use
of
Terminal
software
for
configuration.
ECHO:
Echo
of
received
characters
can
be
switched
on
or
off.
CR:
Replied
strings
are
terminated
by
“\n”
when
setting
is
off
or
“\n\r”
(CR+LF)
when
setting
is
on.
BS:
When
on,
backspace
echo
will
clear
the
“wrong”
character
in
the
Terminal
window
(<BS><SPACE><BS>).
RESPONSE:
Any
response
of
the
PM1122
‐
INT
can
be
disabled
by
switching
RESPONSE
off.
BAUDRATE:
Baud
rate
can
be
changed.
Only
SET
command
can
be
used.
Possible
values
are
2400,
4800,
9600
or
19200.
19200
is
the
default
baudrate.
DBLCLICK:
Setting
of
the
optional
Easywave
radio
receiver,
if
ON,
double
clicking
the
volume
down
knob
on
the
RFKEY
transmitter
will
mute
the
volume.
RFKEY:
Setting
of
the
Easywave
radio
receiver
only.
PRESET:
Presets
can
be
stored,
recalled
and
cleared.
Commands
are
STR,
RCL
and
CLR.
With
store
and
recall,
first
optional
parameter
is
ZONE1
or
ZONE2
and
then
the
preset
number
between
1
and
64.
With
the
CLR
command,
the
only
parameter
is
the
preset
number
that
needs
to
be
cleared
or
“ALL”.
VALFB:
If
this
setting
is
on,
the
PM1122
‐
INT
will
send
a
string
whenever
a
control
is
changed
containing
the
control
name
and
its
value.
6