12
PAGING MICROPHONE
1.
Output level adjustment
: turn the potmeter to adjust the
output level
2.
Output link
: RJ45 connector. Connect multiple DIMIC1/12(S)
units in a daisy chain. The maximum number of units depends
on the capabilities of the master unit. Output (link) and input
are internally hardwired to each other.
3.
Input
: RJ45 connector: connect the DIMIC12 to the master
unit using a standard CAT5 cable.
4.
24 VDC jack
: connect an additional DC adapter here if the
master unit is unable to supply the power for the required
number of microphones. Consult the manual of your master
unit for more details.
Please note that the combination of multiple mics and excessive
CAT5 cable length will cause a substantial voltage drop on the
CAT5 cable. In case of doubt, use a DC adapter as power source for
the microphone/slave.