Attribute

Description

Commands

Value

Factory default

SDQLVL

Volume level

GET, SET, INC, 

DEC

OFF (-64)

-63 to 0

0

MAXLVL

Maximum 

allowed level

GET, SET

BACK, OFF (-64)

-63 to 0

BACK

BALANCE

Left - right 

balance

GET, SET

-31 to 31

0

SELECT

Source selection GET, SET

A, B, AB, or WI

AB

EQBASS

Equalizer bass

GET, SET

-14 to 14

0

EQTREB

Equalizer treble

GET, SET

-14 to 14

0

STANDBY

Standby state

GET, SET

ON or OFF

OFF

IPGAIN

Input gain

GET, SET

0 to 3

A,B,WI at 0

AB at 2

ECHO

RS232 echo 

GET, SET

ON or OFF

OFF

LF

RS232 line feed

GET, SET

ON or OFF

OFF

BS

RS232 

backspace

GET, SET

ON or OFF

ON

VALFB

RS232 value 

feedback

GET, SET

ON or OFF

ON

BACKCT

Back panel 

control

GET, SET

ON or OFF

ON

WALLCT 

Wall panel 

control

GET, SET

ON or OFF

ON

IRRMCT

Infrared remote 

control

GET, SET

ON or OFF

ON

AUTOPW

Auto power off

GET, SET

0 to 30 

0 (OFF)

AUPTRG

Auto power 

trigger level

GET, SET

0 to 9

1

INFO

settings 

information

GET

NA

NA

HWVRSN

Hardware 

version

GET

NA

NA

SWVRSN

Software version GET

NA

NA

RESTORE

Restore factory 

defaults

SET

ON

NA

 RS232 COMMANDS

Содержание SDQ5Pir

Страница 1: ...INFO APART AUDIO COM MANUAL SDQ5Pir ...

Страница 2: ...itor Audio Video applications multimedia applications Powerfull HiFi 5 25 woofer and 1 tweeter Mounting brackets IR remote control and power cord included 2 x 30 watts RMS output power 200 Watts PMPO dynamic Enhanced bass response by DTB reflex tuning Multifunction led indicator standby orange on green overload red off led not lit Hi Q balanced inputs Stereo inputs on standard 3 2 mm mini stereo j...

Страница 3: ... volume control sets the level of the SDQ5Pir speaker 7 Wall panel connector standard RJ45 connector for connection of an optional wall control panel This connection is NOT COMPATIBLE with other networks such as computer networks etc Do not attempt to connect anything else but the optional SDQ5Pir wall control panels 8 Right speaker output output to the passive slave loudspeaker right channel on e...

Страница 4: ...omitted however SDQ5Pir can use and echo LF after a CR Instructions are not case sensitive The 4 possible commands are SET GET INC and DEC With the INC and DEC command a step value can be specified See the table below for details in the value column Operating Settings SDQLVL is the volume level of the speaker system Possible values are OFF mute or any value between 63 lowest and 0 highest volume l...

Страница 5: ...ges sent by SDQ5Pir Please take a look to following example in both cases the user sends the following string get sdqlvl CR With ECHO on and LF off this will be returned by SDQ5Pir get sdqlvl CR command SDQLVL 16 CR reply In case both ECHO and LF are on it will be like this get sdqlvl CR LF SDQLVL 16 CR LF BS is Back Space This is also an ASCII character In case BS and ECHO is on SDQ5Pir will repl...

Страница 6: ...owering up All factory defaults will be restored Standby The SDQ5Pir can be switched to Standby mode with the IR remote control or with the SET STANDBY ON CR instruction Leaving Standby mode can also be done with IR remote controller or the SET STANDBY OFF CR instruction If an RS232 instruction is sent when the amplifier is in Standby mode or during power on and the amplifier is not ready it will ...

Страница 7: ...AIN Input gain GET SET 0 to 3 A B WI at 0 AB at 2 ECHO RS232 echo GET SET ON or OFF OFF LF RS232 line feed GET SET ON or OFF OFF BS RS232 backspace GET SET ON or OFF ON VALFB RS232 value feedback GET SET ON or OFF ON BACKCT Back panel control GET SET ON or OFF ON WALLCT Wall panel control GET SET ON or OFF ON IRRMCT Infrared remote control GET SET ON or OFF ON AUTOPW Auto power off GET SET 0 to 30...

Страница 8: ...from children Dispose of used batteries promptly and as regulated by applicable laws The included infrared remote control unit is powered by a standard CR2025 3V lithium battery Before first use carefully remove the transparent battery saver When the battery is empty replace with the same type only Slide out the battery holder from the remote control unit remove the empty battery and put a fresh o...

Страница 9: ... is 807F Infrared commands have been coded according to the NEC protocol Function ir COMMAND Power ON 12 Power STANDBY 1A Input A 01 Input B 04 Input A B 07 Input WALL 0A Level UP 03 Level Down 06 MUTE 09 Bass UP 0C Bass DOWN 00 Treble UP 0D Treble Down 0F ...

Страница 10: ...l 31 steps 1 25 dB per step Input gain adjustment 0 to 3 3 75 dB per step Output power 2 x 30 watts RMS Frequency range 45 20000 Hz THD 0 07 S N ratio 90 dB Power supply 230 VAC 80 VA max Fuse rating 1 AT 250V Dimensions h x w x d mm 252 x 182 x 170 Net weight 2 85 kg active 1 75 kg slave shipping weight 6 2 kg 1 set shipping dimensions 270 x 210 x 440 accessories supplied Power cord bracket manua...

Страница 11: ...it with the AC ground wire connected to the electrical system ground Have gain controls on amplifiers turned down during power up to prevent speaker damage if there are high signal levels at the inputs Do not connect the inputs outputs of amplifiers or consoles to any other voltage source such as a battery mains source or power supply regardless of whether the amplifier or console is turned on or ...

Страница 12: ...PART AUDIO COM 12 Company names product names and names of formats etc are the trademarks or registered trademarks of their respective owners 2009 APart Audio specifications subject to change without notice ...

Отзывы: