APAR AR232.B Скачать руководство пользователя страница 15

15

 

^

 , 

_

 , 

-

  

symbols used in the presentation of measurement statistics (maximum, minimum and average, chapter 9.3) 

 

StAL

  

cLEA

 

measurement statistics and alarm memory deleted using the 

F

+

START/STOP

  buttons (chapter 9.4, note 4) 

ALAr

  

cLEA 

alarm memory deleted using the 

F

 button, chapter 9.4, 

F button function

 

bLoc   
on

 / 

off

 

lock of the 

START/STOP

 button is on (

on

) or off (

off

), chapter 9.4, 

F button function

 

PASS rESt 

default password restored with

 

 F

+

START/STOP

  buttons during power up (chapter 9) 

Stor Erro 

memory error, e.g. due to filling up or too many files and folders (> 110) or damage to the FAT file system, requiring 
cleaning or formatting the recorder disk with a computer (via USB port), if the problem persists, please send the 
device back to the service for the purpose of repair 

Prob Erro 

sensor's error: no communication with the measuring probe (damage/missing sensor or interruption of electrical 
connections), if the problem persists, the device should be sent back to the service for repair 

 

----

 

bLE   
8888

 / 

oFF

 

Bluetooth interface (BLE) on ( 

8888

 - last 4 characters of the MAC address) or off (

off

 ), chapters 9.4 and 9.4.1,  

F button function

 

bLE

  

Erro 

potential error of the Bluetooth module (additionally indicated by the [BLE] and [NOTE] icons, chapter 6, point b): 
remove the battery for at least 10s, if the problem persists, contact the technical support for additional instructions 
and/or send the device back to the service for repair 

  

12. IMPORTANT EXPLOITATION REMARKS. TROUBLESHOOTING  

!

 

To ensure trouble-free and optimal use of the recorder, read this instruction manual carefully. The description of messages 
and errors reported by the device is included in chapter 11. 

In order to reduce the power consumption and achieve the longest possible working time without replacing the 
batteries, the following recommendations must be observed (estimated working times are given in chapter 4, note 2):

 

- set the highest possible values 

of the 

Data recording interval

 parameter 

(recommended> 1min, chapter 9.2)

 

- turn off the alarms when they are not needed or set 

Alarms interval

 to 5s

 (chapter 9.5, when the buzzer is on every 1s, it   

  additionally increases the power consumption by approx. 15%) 

provide a good range with a connected mobile device and 

turn off Bluetooth communication (BLE) when it is not  

   used (chapter 9.4.1) 
- delete unnecessary files in the internal memory before starting the new recording (and check clock settings)

 

After removing the protective cover, there is also the option of powering up via the USB port (power supply adaptor or 
powerbank, and the battery must be continuously present, because it works as a back-up power supply), however it may 
cause disturbances in the device operation due to reduced resistance to harmful external factors  at the installation site, 
such as water, dust, power grid surges, etc. 
In addition, to ensure trouble-free operation and continuous operation, it is advisable to follow the following instructions: 
- do not disconnect the device from the computer's USB port before the completion of the installation of the drivers and   
   during the communication with the ARSOFT-CFG and LOG programs, as well as when operating the recorder's disk    
   (copying/deleting files, etc.), which is indicated by the [TX/RX] icon on the LCD display, moreover, do not use many   
   ARSOFT applications at the same time 
- do not fill up the memory with your own files and folders because they reduce the capacity for recording data 
- store in external memories (USB, computer disks, etc.) a copy of the current configuration file  
  (

AR23x.B.cfg

/

AR23x.BT.cfg

to

 restore the configuration in case of problems or to duplicate settings 

- don’t unscrew the USB cover, when condensation on the device is possible (e.g. after taking out from the fridge).  
  Wait until the recorder reach ambient temperature, to avoid potential malfunction. If necessary, during this time,   
   recordings can be stopped by programmed START/STOP key (chapter 6) 
- replace the battery with a new one as soon as the device starts to indicate a low voltage level (< 3.1V), chapter 13 
Turned off LCD display may indicate complete discharging, incorrect installation or lack of battery. In this case, open the 
battery cover and check the correctness of the installation and voltage.  

The discharging and replacement or absence of battery causes the clock to be reset and requires the time and date to be 
set again after the power supply is restored (chapters 9 and 9.1), the other configuration parameters remain unchanged. 
 

 

 

Содержание AR232.B

Страница 1: ...6 B AR232 B BATTERY POWERED RECORDERS OF HUMIDITY AND OR TEMPERATURE Version 2 0 4 2019 03 13 APAR SALES OFFICE 05 090 Raszyn ul Ga czy skiego 6 Tel 22 101 27 31 22 853 49 30 E mail automatyka apar pl...

Страница 2: ...E INSTALLATION 8 9 SETTING CONFIGURATION PARAMETERS 8 9 1 INTERNAL CLOCK OPTIONS 9 9 2 RECORDING OPTIONS 9 9 3 DISPLAY AND MEASUREMENTS OPTIONS 10 9 4 BUTTONS FUNCTIONS AND ACCESS OPTIONS 11 9 4 1 HAN...

Страница 3: ...vice portable casingwith a handle for easy mounting on vertical and horizontal surfaces after using an additional table base or other user s solutions two line readable LCD display with icons and meas...

Страница 4: ...u can also buy it through the online storeapar sklep pl 3 6V lithium battery type AA R6 2450mAh e g SAFT type LS14500 table base standing NOTE before working with the recorder read this user manual pe...

Страница 5: ...etails inchapter 5 77x111x32 mm withoutprobe and hanging holder Operating position any positionor sensor cover down whenthe probe is exposed to directcontact with water Weight 150g withbattery and pro...

Страница 6: ...r when condensation on the device is possible e g after taking out from the fridge Wait until the recorder reach ambient temperature to avoid potential malfunction If necessary during this time record...

Страница 7: ...iconof the USB transmissionand recording readingof the recorder s memory 6 saving the archive file is active REC registrationstatus icon missing in progress or pause registration options are describe...

Страница 8: ...ice from the computer before the installationof the drivers is completed connection of the recorder to the USB portof the computer stops the recordinguntil the cable is disconnected and blocks a previ...

Страница 9: ...urry or late Dischargingand replacementor lackof battery causes the clock to be reset and requires setting time and date againafter the power is restored Table 9 1 Parameters of the internal time cloc...

Страница 10: ...r calculated value dew frostpoint to besaved inthe archive file descry ptionoftherecord in chapter10 sensor s temperature C dew frostpointtemperature C F sensor stemperature C F Notes 1 the recordingi...

Страница 11: ...in AR232 B 9 4 BUTTONS FUNCTIONS AND ACCESS OPTIONS Table 9 4 Configurationparameters regarding buttonfunctions and access options Parameter Rangeofparametervariabilityanddescription Default settings...

Страница 12: ...the Bluetoothparameter to be setto on value or programmingthe F button functionwith the Bluetoothturnon off value chapter 9 4 The recorder is visible under the name Smart Humigadget and can be connect...

Страница 13: ...egligible Table 9 5 Configuration parameters regarding alarm configuration Parameter Rangeofparametervariabilityanddescription Default settings Alarmtypeforrelative humidity 1 and Alarmtypeforsensor s...

Страница 14: ...ence number date time event identifier argument 1 argument 2 checksum Sample record for humidity and temperature measurement 20 2018 05 09 13 46 30 5 40 4 26 3 IEM1 where argument 1 40 4 RH argument 2...

Страница 15: ...ood range with a connected mobile device and turnoff Bluetoothcommunication BLE when it is not used chapter 9 4 1 delete unnecessary files inthe internal memory before starting the new recording and c...

Страница 16: ...r replace the battery with a newone of the appropriate type 3 6V AA chapter 4 with polarity in the holder screw the battery cover in place with the 2 screws with properly installed o rings NOTE when t...

Отзывы: