Genlock Tab:
Genlock Position - Vertical:
The vertical offset can be adjusted using either moving the slider bar control with a mouse, or by the up or down
arrow buttons adjacent to the number on the right of the slider bar.
Genlock Position - Horizontal:
The horizontal offset can be adjusted using either moving the slider bar control with a mouse, or by the up or down
arrow buttons adjacent to the number on the right of the slider bar.
Genlock:
The OG-US-4000 model includes the feature of locking the output video signal timing to the openGear frame’s refer-
ence signal. This feature can be Enabled or Disabled. (Also refer to the Signal tab section)
Notes:
Genlock adjustments require the use of external test equipment.