Panel functions

1

2

VCC

+24VDC

3

RS485+B

4

RS485+A

5

GND

6

GND

7

8

9

PE

LCD parameter display description

Display 

content

D

escription

 

Sample graph

RUN/STOP

Run / Pause 

A00

Current w

orking address of the device

00

S5

Current w

ind speed gear

5

T01

Cleaning cycle

01

Unit

H

F2 F1

Current air outlet 

(

There are 1 to 4 air outlets for AP-DJ28 

series ionizing air blower

)

+07 -08

The balance voltage of the corresponding air outlet

28

Temperature of the current operating environment

62%RH

Humidity of the current operating environment

Cleaning...

Cleaning indication

Fan Fault!!!

Fan fault alarm

HV Warning!!!

High voltage fault alarm

Green light

Running

Blue light

Pause / Standby

Blue light flashes

Cleaning

Red light

Fan fault alarm

Red light fashes

HV alarm

Product Use

Panel functions/specification/dimensions

Power interface cable function information

Orange/White-orange

Blue

White-blue

Green

White-green

Brown

VTH

Sensor threshold alarm 

HV

AL

Eliminator high voltage alarm

White-brown  

Clean

Eliminator cleaning indication

Metal shield

 

ACT

Sensor/eliminator  power-on indication

The output wiring diagrams of pins 7 and 8 are as follows:

HV Alarm signal:Normal--always open

Abnormal--always close

Power signal :Normal--always close

cleaning signal:Clean--always open

U-shaped bracket

RJ45 power/communication interface

Ground Stud

Power switch

Air volume adjustment

LCD display

Status Indicator

Front

Back

Cleaning switch 

Bakelite screw 

handle

M5×8

Содержание AP-DJ2811

Страница 1: ...Intelligent Control Network LED Display Ionizing Air Blower AP DJ2811 Shanghai Anping Static Technology Co Ltd AP TR AP T New Product Intelligent Control Network LED Display Ionizing Air Blower...

Страница 2: ...ms caused by static electricity Suitable for electronics optoelectronics semiconductor and other industries Static removal Prevent blockage of feeder Prevent static electricity Prevent material splash...

Страница 3: ...ring Monitoring the working status of ionizing air blower online RS485 communication AP DY6703 AP KT3701 AP DY6704 USB wire link USB wire link IMS monitoring software IMS monitoring software IMS monit...

Страница 4: ...Button Function instructions Unlock Run Pause Clean Adjust clean time Adjust air volume Adjust ion balance Confirm Reset Unlock before adjusting operating parameters 30s delay if any key is pressed ex...

Страница 5: ...of the object Increase Tp so that the positive voltage acting capacity becomes greater and the acting time becomes longer More positive ions and less negative ions output to neutralize the excess nega...

Страница 6: ...he 0 point of the test length is the center position of the air blower Test standard ANSI ESD STM3 1 SJ T 11446 2013 Test instrument Trek charge plate tester Test voltage 1000V 100V attenuation Test e...

Страница 7: ...ly brushed every 4 hours for manual cleaning and maintenance free Fault alarm Display screen show fault alarm and LED red light alarm when the fan ion balance and high voltage breakdown No 5 Network M...

Страница 8: ...cing function The self balancing range is 10V and the balance voltage can be displayed in real time Intelligent remote control The negative high voltage amplitude is adjustable which can be used to ad...

Страница 9: ...m Green light Running Blue light Pause Standby Blue light flashes Cleaning Red light Fan fault alarm Red light fashes HV alarm Product Use Panel functions specification dimensions Power interface cabl...

Страница 10: ...pecification Installation accessories 1 pair of U shaped aluminum powder spraying mounting brackets 1 pair of bakelite screw handles M5 8 Unit mm Dimensions Model Input voltage Input voltage Output vo...

Страница 11: ...ries 1 Place the ionizing air blower in the work area where static electricity is to be eliminated and the installation angle is perpendicular to the surface of the charged body 2 Ionizing air blower...

Страница 12: ...Faults The indicator on the fan panel is off The electrostatic removal performance decreased obviously The electrostatic removal performance decreased High voltage ion balance alarm Panel indicator l...

Страница 13: ...repairing 2 Do not press or rotate the control buttons on the fan panel too hard otherwise the device will be permanently damaged 3 If the working indicator light on the front panel of the fan is off...

Страница 14: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Отзывы: