Intelligent Remote Control
Ion balance/ion output frequency adjustable
Button function instructions
Unlock
Unlock before adjusting operating parameters
Run / Pause
Device starts running when power is on. Press "STOP" to standby and no
high voltage output. Press "RUN" again and the device will start working.
Adjust cleaning
cycle
CT
TH
→ +/-
Press CT
TH
first, then press +/- to increase or decrease the cleaning cycle.
The default cleaning cycle is 15 days, and the adjustment range is 1-60
days;The cleaning function will alarm and the power will be restarted to
restore the set time when the countdown is 0 days; the cleaning function
will be invalid when it is set to 0 days.
Adjust frequency FREQ → +/-
Press FREQ first, then press +/- to increase or decrease the output frequency
of positive and negative ions(cycle setting). Note: This adjustment function
can only be effective if the coding switch is in C or D position.
Adjust balance
IB
N
→ +/-
Press IBN first, then press + when the positive voltage on flat panel
detector or discharge object surface is high, press IBN first, then press
- when the negative voltage on flat panel detector or discharge object
surface is high until the ion balance reaches the ideal status.
Confirm
CAL → OK
Note: Press CAL first, then press OK to confirm after adjusting the output
parameter; otherwise, false alarms are likely to occur.
Reset
CAL →
Reset
,
Press CAL first
,
then press
Note: The discharge effect will be improved if the ion balance (output) is adjusted to the opposite polarity of the charged object in the case where the static charge with a certain polarity is attached to
the static charge removal object in advance. However, be careful not to charge the object back in this case.
Function
Symbol
Operation instructions