The ion bar should be cleaned and maintained in time according to the use environment and the required electrostatic protection
requirements in order to ensure the good performance of the product. That is, unscrew the electrode needle assembly into an ultrasonic
cleaner and ultrasonically clean for 10 minutes. Ultrasonic cleaning will remove dust particles attached to the electrode needles as well as
most of the white crystal attachments which will improve its performance significantly.
1
、
Note:
A
、
peration must be done 10 minutes after power cut off.
B
、
The ultrasonic cleaning fluid is pure water, not corrosive solvents such as circuit board cleaning agents, otherwise it will corrode the
plastic electrode holder.
C
、
The ion bar must be powered on after moisture is completely volatilized after cleaning.
2
、
If the working indicator light of the power plug-in port on the end cover of the bar body and the panel indicator light are off, it should be
stopped and repaired by professional maintenance personnel. It can be used only after the electrical performance index is normal.
Maintenance
After-sales service
AP-
DB1223
space
ion bar has undergone rigorous testing and aging treatment before ex-work. Its performance has
completely reached the relevant indicators marked in the usage instruction.
1.
AP&T makes a commitment to the customer that any defective parts inspected by AP&T will be repaired or replaced free of charge
within one year from the date of purchase. However, this commitment does not apply to:
(1)
The device is incorrectly used or installed.
(2)
Damage caused by negligence or accident during use.
(3)
Modified, disassembled or repaired by other service departments not authorized by Anping Company.
2.
The
discharge
electrode is a consumable product which is not included in the scope of warranty and will be charged for replacement
when
repairing.
3.
AP&T shall not be liable for any incorrect use of the products except for repair or replacement of parts as specified above.