Static removing
performance decline
obviously
Pollute or damage of
discharge pin
Clean or replace discharge pin
Electrode pad not tightly
screwed
Be sure the electrode pad screwed
tightly
Improper installation
position
Confirm the optimum installation
position
3
Static removing
performance decline
There are conductor or
other ion bar around
Remove conductor or other ion bar
4
HV Alarm
Electromagnetic disturb
Switch off and reset
Abnormal discharge
Check installation position and be
away from conductors
Pollute or damage of
discharge pin
Send back to manufacturer
5
Smoking or burning
Pollute or damage of
discharge pin or electrode
pad insulator
Send back to manufacturer
6. Maintenance
**************************************
(1) User should clean and maintain timely to ensure the good performance of
the product according to working environment and requirement of ESD
protection. Clean the carbon materials on electrode tip, discharge pad and
metal discharge body with static brush or clean cloth with ethanol can
obviously improve the performance.
Caution
:
A
、
Must be done after the power is shut done for 10 minutes
B
、
Restart must wait till alcohol completely volatilized after cleaning by
clean cloth with ethanol. Any other organic solution is not allowed
to be used to clean the rod.
(2) Stop using when POS/NEG working indication keeps off. Re-use after
check and repair by professionals.
7. Accessories
***************************************
1. Installation bracket 2. Power adapter 3. Power cord 4. Three-core power cord
1
、
General
*************************************
AP-AB1208 Air source AC pulse ion bar is the newest developed bar type
static eliminator for static removing.
It can be widely used in electronics, textile, optical and other industries.
2
、
Features
***********************************
(1) Bar shaped and cross over static eliminator
(2) Manufactured by using the latest patented technology of static removing.
(3) Fast speed of static removing, low ion balance and high safety.
(4) LCD on bar body indicates working status for easy use and maintenance
(5) Output voltage adjustable, fit for different static environment.
(6) With alarm function of ion volume, electrode tip cleaning and high voltage
fault.
3
、
Parameter
***************************************
Model
AP-AB1208
Output voltage
AC±5KV
Output frequency
5,30Hz(default)
Duty factor
10%-90%
Power
10W
Working distance
100-1000mm
Ion balance
≤|±30V| ( AVE )
Discharge time
≤2S(adjust)
Working temperature
0℃-50℃
Working humidity
<70%
Air pressure scope
0.1-0.6MPa
Cord length
2.5m
Bar length