background image

2

Static removing

performance decline

obviously

Pollute or damage of

discharge pin

Clean or replace discharge pin

Electrode pad not tightly

screwed

Be sure the electrode pad screwed

tightly

Improper installation

position

Confirm the optimum installation

position

3

Static removing

performance decline

There are conductor or

other ion bar around

Remove conductor or other ion bar

4

HV Alarm

Electromagnetic disturb

Switch off and reset

Abnormal discharge

Check installation position and be

away from conductors

Pollute or damage of

discharge pin

Send back to manufacturer

5

Smoking or burning

Pollute or damage of

discharge pin or electrode

pad insulator

Send back to manufacturer

6. Maintenance

**************************************

(1) User should clean and maintain timely to ensure the good performance of

the product according to working environment and requirement of ESD
protection. Clean the carbon materials on electrode tip, discharge pad and
metal discharge body with static brush or clean cloth with ethanol can
obviously improve the performance.

Caution

A

Must be done after the power is shut done for 10 minutes

B

Restart must wait till alcohol completely volatilized after cleaning by
clean cloth with ethanol. Any other organic solution is not allowed
to be used to clean the rod.

(2) Stop using when POS/NEG working indication keeps off. Re-use after

check and repair by professionals.

7. Accessories

***************************************

1. Installation bracket 2. Power adapter 3. Power cord 4. Three-core power cord

1

General

*************************************

AP-AB1208 Air source AC pulse ion bar is the newest developed bar type

static eliminator for static removing.

It can be widely used in electronics, textile, optical and other industries.

2

Features

***********************************

(1) Bar shaped and cross over static eliminator
(2) Manufactured by using the latest patented technology of static removing.
(3) Fast speed of static removing, low ion balance and high safety.
(4) LCD on bar body indicates working status for easy use and maintenance
(5) Output voltage adjustable, fit for different static environment.
(6) With alarm function of ion volume, electrode tip cleaning and high voltage

fault.

3

Parameter

***************************************

Model

AP-AB1208

Output voltage

AC±5KV

Output frequency

5,30Hz(default)

Duty factor

10%-90%

Power

10W

Working distance

100-1000mm

Ion balance

≤|±30V| ( AVE )

Discharge time

≤2S(adjust)

Working temperature

0℃-50℃

Working humidity

<70%

Air pressure scope

0.1-0.6MPa

Cord length

2.5m

Bar length

380mm,410mm,460mm,510mm……2510mm(spacing distance 50mm)

Отзывы: