PURPOSE 

S19-P  is  microprocessor  controller  for  multi-spot  12V/24V  LED  lighting,  intended  for  LED  lighting  of 

staircases  (and  other  passageways),  with  a  separate  control  of  each  lamp.  The  device  turns  on  the 

consecutive LED lamps, and turns them off after a specified time. In the case of dimmable lamps, the 

turning  on  and  off  happens  gradually  and  smoothly.  The  controller  can  also  provide  gentle  backlight 

lighting as well as react to motion and dusk. 

S19-P is equipped with: 

 

built-in  configurator  capable  of  setting  18  parameters,  e.g.  brightness;  timing,  speed,  and 

smoothness of turning on/off; warning when the lights are about to turn off; and many more, which 

enables the users to set the device up according to their needs; 

 

integrated dusk switch (IDS) which disables the controller during daylight, with a light sensor that can 

be installed both indoors and outdoors. 

2

 

DESCRIPTION 

2.1

 

Terminals 

The controller’s terminals are depicted below. 

Содержание smartLEDs PREMIUM S19-P

Страница 1: ...Directive 2012 19 EU on waste electrical and electronic equipment WEEE it is forbidden to place with other waste any waste equipment marked with a crossed out bin symbol The user wanting to get rid o...

Страница 2: ...adually and smoothly The controller can also provide gentle backlight lighting as well as react to motion and dusk S19 P is equipped with built in configurator capable of setting 18 parameters e g bri...

Страница 3: ...ed that they are supplied from a DC SELV power supply up to 24 V with a galvanic insulation of the output voltage from the mains supply The maximum current must not exceed 2 A per single output The ou...

Страница 4: ...ng on 2 4 2 Lights on When the lights are on they remain on for a time predefined by the On time parameter The time extends when a new signal appears at any of the inputs 2 4 3 Warning When the time d...

Страница 5: ...ing by removing the front cover 3 2 2 Restart the controller Restart the controller by pressing the RESET button shortly both signalling diodes RED and GREEN will turn on for about 3 sec 3 2 3 Put con...

Страница 6: ...ep in order to repeat all the steps and correct the settings press the SET button briefly under 2 seconds Choose the desired value of the Decision parameter with the and buttons then press and hold th...

Страница 7: ...ble lamps the parameter must be set to 0 then there is no backlight lighting and the turning on and off proceeds in a one by one switching fashion 3 4 8 Brigthness The brightness of the LED lamps CAUT...

Страница 8: ...witch blocks the controller CAUTION Setting the parameter to one of S1 S10 with the sensor disconnected will result in the controller not being blocked during daylight CAUTION For the built in dusk sw...

Страница 9: ...not dimmable turned on together with the first lamp SWITCH BEFORE 2 4 Master not dimmable turned on before the first lamp Number of warnings 0 3 not flashing no warnings 1 3 1 1 warning 2 3 2 2 warni...

Страница 10: ...11 90 max brightness 100 8 12 100 max brightness Backlight lighting 0 9 not flashing no backlight lighting 2 9 1 2 brightness 5 9 2 5 brightness 10 9 3 10 brightness 20 9 4 20 brightness 30 9 5 30 bri...

Страница 11: ...g on time 9s 12s 12 8 turning on time 12s 18s 12 9 turning on time 18s 24s 12 10 turning on time 24s On time 0s 13 not flashing no lights on phase 4s 13 1 on time 4s 10s 13 2 on time 10s 20s 13 3 on t...

Страница 12: ...evel of DIS disables the controller ENABLE 18 1 active level of DIS enables the controller TOGGLE 18 2 active level toggles DIS input S1 18 3 threshold brightness S1 S2 18 4 threshold brightness S2 S3...

Страница 13: ...may result in burning of the controller Please ensure that any control device e g motion sensors including those powered with 12V do not apply any voltage onto these inputs CAUTION We advise particul...

Страница 14: ...manipulations and changes in the installation with the power off Even a short term occurrence of voltage on the wrong outlet of the controller can permanently damage the controller and such damage is...

Страница 15: ...smartLEDs S19 P User manual v5 0 6 APACHETA Smart Systems str 15 15...

Отзывы: