APACHETA smartLEDs PREMIUM S19-P Скачать руководство пользователя страница 12

S19-P  

 User manual v5.0.6

    

 

smart

L

E

D

s

 

 

str. 12/15 

 

© APACHETA Smart Systems

 

 

4s 

15 

waiting time: 4s 

 

6s 

15 

waiting time: 6s 

 

9s 

15 

waiting time: 9s 

 

12s 

15 

waiting time: 12s 

 

18s 

15 

waiting time: 18s 

 

24s 

15 

10 

waiting time: 24s 

Turning-off time 

 

 

 

 

 

0s 

16 

not flashing 

simultaneous turning-off 

 

0,4s 

16 

turning-off time: 0,4s 

 

1s 

16 

turning-off time: 1s 

 

2s 

16 

turning-off time: 2s 

 

3s 

16 

turning-off time: 3s 

 

4s 

16 

turning-off time: 4s 

 

6s 

16 

turning-off time: 6s 

 

9s 

16 

turning-off time: 9s 

 

12s 

16 

turning-off time: 12s 

 

18s 

16 

turning-off time: 18s 

 

24s 

16 

10 

turning-off time: 24s 

Active level 

 

 

 

 

 

ZERO 

17 

not flashing 

connected to GND 

 

ONE 

17 

disconnected from GND 

DIS input 

 

 

 

 

 

DISABLE 

18 

not flashing 

active level of DIS disables the 

controller 

 

ENABLE 

18 

active level of DIS enables the 

controller 

 

TOGGLE 

18 

active level toggles DIS input 

 

S1 

18 

threshold brightness S1 

 

S2 

18 

threshold brightness S2 

 

S3 

18 

threshold brightness S3 

 

S4 

18 

threshold brightness S4 

 

S5 

18 

threshold brightness S5 

 

S6 

18 

threshold brightness S6 

 

S7 

18 

threshold brightness S7 

 

S8 

18 

10 

threshold brightness S8 

 

S9 

18 

11 

threshold brightness S9 

 

S10 

18 

12 

threshold brightness S10 

Decision? 

 

on 

any 

SET pressed <2s – continue 
configuration – move to step 1 

 

SAVE 

on 

SET pressed >4s (until GREEN diode 
stops blinking) – save new settings and 
finish configuration 

 

QUIT 

on 

SET pressed >4s (until GREEN diode 
stops blinking) – quit configuration 
without saving new settings 

 

RESTORE 

on 

SET pressed >4s (until GREEN diode 
stops blinking) – restore factory settings 
and finish configuration 

normal function 

 

free 

free 

„+” „-” and SET buttons released 

Содержание smartLEDs PREMIUM S19-P

Страница 1: ...Directive 2012 19 EU on waste electrical and electronic equipment WEEE it is forbidden to place with other waste any waste equipment marked with a crossed out bin symbol The user wanting to get rid o...

Страница 2: ...adually and smoothly The controller can also provide gentle backlight lighting as well as react to motion and dusk S19 P is equipped with built in configurator capable of setting 18 parameters e g bri...

Страница 3: ...ed that they are supplied from a DC SELV power supply up to 24 V with a galvanic insulation of the output voltage from the mains supply The maximum current must not exceed 2 A per single output The ou...

Страница 4: ...ng on 2 4 2 Lights on When the lights are on they remain on for a time predefined by the On time parameter The time extends when a new signal appears at any of the inputs 2 4 3 Warning When the time d...

Страница 5: ...ing by removing the front cover 3 2 2 Restart the controller Restart the controller by pressing the RESET button shortly both signalling diodes RED and GREEN will turn on for about 3 sec 3 2 3 Put con...

Страница 6: ...ep in order to repeat all the steps and correct the settings press the SET button briefly under 2 seconds Choose the desired value of the Decision parameter with the and buttons then press and hold th...

Страница 7: ...ble lamps the parameter must be set to 0 then there is no backlight lighting and the turning on and off proceeds in a one by one switching fashion 3 4 8 Brigthness The brightness of the LED lamps CAUT...

Страница 8: ...witch blocks the controller CAUTION Setting the parameter to one of S1 S10 with the sensor disconnected will result in the controller not being blocked during daylight CAUTION For the built in dusk sw...

Страница 9: ...not dimmable turned on together with the first lamp SWITCH BEFORE 2 4 Master not dimmable turned on before the first lamp Number of warnings 0 3 not flashing no warnings 1 3 1 1 warning 2 3 2 2 warni...

Страница 10: ...11 90 max brightness 100 8 12 100 max brightness Backlight lighting 0 9 not flashing no backlight lighting 2 9 1 2 brightness 5 9 2 5 brightness 10 9 3 10 brightness 20 9 4 20 brightness 30 9 5 30 bri...

Страница 11: ...g on time 9s 12s 12 8 turning on time 12s 18s 12 9 turning on time 18s 24s 12 10 turning on time 24s On time 0s 13 not flashing no lights on phase 4s 13 1 on time 4s 10s 13 2 on time 10s 20s 13 3 on t...

Страница 12: ...evel of DIS disables the controller ENABLE 18 1 active level of DIS enables the controller TOGGLE 18 2 active level toggles DIS input S1 18 3 threshold brightness S1 S2 18 4 threshold brightness S2 S3...

Страница 13: ...may result in burning of the controller Please ensure that any control device e g motion sensors including those powered with 12V do not apply any voltage onto these inputs CAUTION We advise particul...

Страница 14: ...manipulations and changes in the installation with the power off Even a short term occurrence of voltage on the wrong outlet of the controller can permanently damage the controller and such damage is...

Страница 15: ...smartLEDs S19 P User manual v5 0 6 APACHETA Smart Systems str 15 15...