![APACHETA smartLEDs PREMIUM S19-P Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/apacheta/smartleds-premium-s19-p/smartleds-premium-s19-p_user-manual_2951860012.webp)
S19-P
User manual v5.0.6
smart
L
E
D
s
str. 12/15
© APACHETA Smart Systems
4s
15
5
waiting time: 4s
6s
15
6
waiting time: 6s
9s
15
7
waiting time: 9s
12s
15
8
waiting time: 12s
18s
15
9
waiting time: 18s
24s
15
10
waiting time: 24s
Turning-off time
0s
16
not flashing
simultaneous turning-off
0,4s
16
1
turning-off time: 0,4s
1s
16
2
turning-off time: 1s
2s
16
3
turning-off time: 2s
3s
16
4
turning-off time: 3s
4s
16
5
turning-off time: 4s
6s
16
6
turning-off time: 6s
9s
16
7
turning-off time: 9s
12s
16
8
turning-off time: 12s
18s
16
9
turning-off time: 18s
24s
16
10
turning-off time: 24s
Active level
ZERO
17
not flashing
connected to GND
ONE
17
1
disconnected from GND
DIS input
DISABLE
18
not flashing
active level of DIS disables the
controller
ENABLE
18
1
active level of DIS enables the
controller
TOGGLE
18
2
active level toggles DIS input
S1
18
3
threshold brightness S1
S2
18
4
threshold brightness S2
S3
18
5
threshold brightness S3
S4
18
6
threshold brightness S4
S5
18
7
threshold brightness S5
S6
18
8
threshold brightness S6
S7
18
9
threshold brightness S7
S8
18
10
threshold brightness S8
S9
18
11
threshold brightness S9
S10
18
12
threshold brightness S10
Decision?
on
any
SET pressed <2s – continue
configuration – move to step 1
SAVE
on
1
SET pressed >4s (until GREEN diode
stops blinking) – save new settings and
finish configuration
QUIT
on
2
SET pressed >4s (until GREEN diode
stops blinking) – quit configuration
without saving new settings
RESTORE
on
3
SET pressed >4s (until GREEN diode
stops blinking) – restore factory settings
and finish configuration
normal function
free
free
„+” „-” and SET buttons released